CLEANING & MAINTENANCE
WARNING:
KEEP WATER AND SOLUTIONS OUT OF CONTROLS.
NEVER SPRAY OR HOSE CONTROL CONSOLE,
ELECTRICAL CONNECTIONS, ETC.
CAUTION:
MOST CLEANERS ARE HARMFUL TO THE SKIN,
EYES, MUCOUS MEMBRANES AND CLOTHING.
PRECAUTIONS SHOULD BE TAKEN TO WEAR
RUBBER GLOVES, GOGGLES OR FACE SHIELD AND
PROTECTIVE CLOTHING. CAREFULLY READ THE
WARNING AND FOLLOW THE DIRECTIONS ON THE
LABEL OF THE CLEANER TO BE USED.
7.1 Daily Cleaning (after each meal)
Always start with a cold unit.
The stainless interiors can easily be cleaned using a non-etching solution.
Follow the manufacturer's instructions when using any cleaner.
Care should be taken to prevent caustic cleaning compounds from coming in
contact with aluminized steel.
To clean the rack, remove it from the unit and soak it in a solution of ammonia and
water.
The stainless front should normally be cleaned with a soap and water solution.
Discoloration or heat tint may be removed with any of the following cleaners:
Penny Bright
Copper Bright
Du-Bois Temp
, or Past Nu-Steel
.
Always apply these cleaners when the unit is cold and rub in the direction of the
metal's grain.
CAUTION:
Never spray liquids on the quartz elements as this can
weaken the element and break the glass.
7.2 Maintenance
ELEMENT REPLACEMENT
Quartz Elements are replaced as follows:
De-energize unit and open power supply breaker.
Remove rack and set to one side.
Remove three (3) screws from each element bracket. Brackets support each end of
the elements. One or both brackets may be removed.
Remove ceramic wire nuts from both ends of the element, label wires as necessary
to allow ease of reconnection.
To check each element, use an ohmmeter and check for continuity from one end of
the element to the other. If an element is found without continuity
(open)
, replace
this element.
Hold elements in position and connect wires as they were removed. Use new
"Ceramic"
wire nuts to reconnect elements.
Re-install bracket supporting element ends.