OPTIONAL EQUIPMENT INSTRUCTIONS
Changing The Password
Select a new password using the
UP
and
DOWN
buttons.
Press the
*
/FUNC
button until the word “
SEt
” appears in
the display. Release the
*
/FUNC
button. The number in
the display is your new pass code. Make sure you record
this number. Press and hold the
*
/FUNC
button until the
word “
dIS
” appears in the display.
If the password is forgotten, it can be disabled by
removing the batteries. The password is intended for
rental units. It is recommended that a seal be affixed to
the rear plate of the acre counter to determine if the
settings have been tampered with.
Quick-start Settings for Loup Acre
Meters Prior to 05/15/2012
• When the meter is set to “count” mode in pulses screen,
meter will register only magnetic wheel revolutions.
• The meter must be in sleep mode (blank screen) to
calculate acres or to count pulses.
• The count screen must have a value other than zero
(0000) to scroll to other modes or screens.
• To reset the FIELD ACRES screen to zero (0000), press
the up and down buttons simultaneously.
To Program Meter
1.
Press the function button to scroll to pulses screen.
2.
Enter the number of pulses using the up or down
buttons for the model listed in the chart. See Table .
3.
Press the function button to set the pulses. (If screen
goes blank before you press the function button,
repeat steps 1 and 2).
4.
Press the function button to scroll to the width
screen.
5.
Enter the width of seeder using the up or down
buttons for the model listed in the chart. See Table .
6.
Press the function button to set the width. (If screen
goes blank before you press the function button,
repeat steps 4 and 5).
7.
Press the function to scroll through the screens to
check that the correct pulses and width have been
entered.
To Enter Password
1.
Press the function button to scroll to password
screen.
2.
Pick a numeric password and enter it by using the up
or down buttons, until your password is displayed.
3.
Press the function button to set password; screen will
show “(set)”. Record number - it is required if you
decide to disable password.
4.
Let screen go blank - password is now entered.
5.
Press the function button to scroll to the password
screen it will show (ent). If the screen does not show
(ent), repeat steps 2, 3 and 4.
To Disable Password
1.
Press the function button to scroll to the password
screen it will show (ent).
2.
Use up or down button to enter password (number).
3.
Press the function button to scroll around to pass
screen again. Number entered in step 2 will appear.
4.
Press up or down button to enter 0.
5.
Press the function button; (dis) will appear. Password
is now disabled.
Battery Replacement
The battery operated acre counter uses 3 AA batteries.
The batteries should last between 5 and 10 years. The
acre counter will last much longer than that. Eventually,
you will have to replace the batteries. The “
BATT
” LED
will light when the batteries require replacement. Remove
the acre counter from the implement and undo the 4
screws on the back of the case. This will separate the
housing from the rear plate. Replace the batteries with 3
high quality AA alkaline batteries.
This unit is dust and splash resistant, under no
circumstances should this unit be submerged in any
conductive, corrosive, or flammable liquid.
Содержание Till 'N Seed BPS6
Страница 2: ......
Страница 10: ...1 6 3P091 SAFETY INFORMATION Figure 1 4 Decals 2 of 5 30 5 1 3 45 1 1 30 4 5 1 1 1 0 05 5 1 1 30 5 3...
Страница 14: ...1 10 3P091 SAFETY INFORMATION Figure 1 8 Slow Moving Vehicle Sign SMV SIGN P N 2P151 FRONT...
Страница 19: ...OPERATION 2 5 Figure 2 5 Front Seedbox Seed Chart 2 of 2...
Страница 32: ...2 18 3P091 OPERATION Page Intentionally Blank...
Страница 42: ...3 10 3P091 OPTIONAL EQUIPMENT INSTRUCTIONS Table provided for general use NOTES...
Страница 54: ...4 12 3P091 MAINTENANCE Table provided for your general use with this manual NOTES...
Страница 56: ...5 2 3P091 REFERENCE TABLES AND SPECIFICATIONS Table provided for your general use with this manual NOTES...