COMPONENT OVERVIEW
2-11
The motor is located on the streetside center interior of the
enclosure, behind the vent and front covers. It is a 7.7kw,
29vac 3 phase internal air cooled variable speed induction
motor to provide power to the hydraulic pump. The
motor’s rpm is regulated by the controller and will fluctuate
during operation to protect the motor and batteries. The
motor and pump assembly runs constantly while the key
switch is in the “ON” position.
Requires complex electrical system troubleshooting and
repair. It is highly recommended to contact the Landoll
Trailer Service Department at
Landoll.com
or phone
800-446-5175 / 888-522-3634. For more information,
resource the Manufactures References,
Manufacturer Index on Page 6-1.
Hydraulic Hoses
WARNING
The hydraulic hoses and quick couplers are located on
the streetside exterior left frame panel of the enclosure,
just to the left of the charging port. When coupled to the
equipment, they provide the hydraulic pressure and return
paths needed to operate the equipment’s hydraulic
features,
Figure 2-12: Hoses & Couplers
Hydraulic Pressure
Transducers
There are two pressure transducers, one is mounted on
the pump pressure output port. The other is mounted on
the LS port of the main hydraulic manifold. They monitor
system working pressure and communicate with the
controller, regulating system pressure to conserve battery
power and motor temperature. When hydraulic operations
are paused, the system will slow down motor rpm’s
reducing system pressure. When hydraulic operations
resume, the system will speed up motor rpm’s increasing
system pressure.
Figure 2-13: Hydraulic Pressure Transducers
Hydraulic Pump
WARNING
The hydraulic pump is located on the streetside center
interior of the enclosure mounted to the electric motor. It
Failure to comply may lead to death, serious
injury or damage to equipment. For service and
repairs, it is highly recommended to contact the
Landoll Trailer Service Department at
Landoll.com or phone 800-446-5175 /
888-522-3634.
1.
Damage will occur if the power unit’s
hydraulic hoses are not coupled before
turning “ON” the motor and pump assembly.
Hoses must be coupled together or to the
equipment couplers.
STREETSIDE FRONT VIEW
MALE COUPLER & RETURN HOSE
FEMALE COUPLER & PRESSURE HOSE
Failure to comply may lead to death, serious
injury or damage to equipment. For service and
repairs, it is highly recommended to contact the
Landoll Trailer Service Department at
Landoll.com or phone 800-446-5175 /
888-522-3634.
1.
DO NOT touch, surface may be hot.
TRANSDUCERS
MAIN HYDRAULIC
MANIFOLD
PUMP
Содержание EHP
Страница 6: ...iv F 1153 2308 TABLE OF CONTENTS...
Страница 24: ...3 4 F 1153 2308 OPERATION TABLE OF CONTENTS Table provided for general use NOTES...
Страница 29: ...MAINTENANCE AND LUBRICATION 4 5 TABLE OF CONTENTS Table provided for general use NOTES...
Страница 31: ...MAINTENANCE AND LUBRICATION 4 7 TABLE OF CONTENTS Table provided for general use NOTES...
Страница 37: ...MAINTENANCE AND LUBRICATION 4 13 TABLE OF CONTENTS Table provided for general use NOTES...
Страница 42: ...4 18 F 1153 2308 MAINTENANCE AND LUBRICATION TABLE OF CONTENTS Table provided for general use NOTES...
Страница 45: ...TROUBLESHOOTING GUIDE 5 3 TABLE OF CONTENTS Table provided for general use NOTES...
Страница 50: ...5 8 F 1153 2308 TROUBLESHOOTING GUIDE TABLE OF CONTENTS Table provided for general use NOTES...
Страница 52: ...6 2 F 1153 2308 MANUFACTURER REFERENCES TABLE OF CONTENTS Table provided for general use NOTES...