The desired temperature is not reached. / The flame is
small or flickers a lot or the flame pattern is irregular. /
Individual burners do not ignite.
The gas cylinder is (almost) empty.
►
Replace the gas cylinder.
The burners are blocked.
►
Clean them in the manner described in the “Cleaning and
Maintenance” chapter – “Cleaning Gas-Carrying Components
(If Necessary)”.
The gas hose is bent.
►
Straighten the gas hose.
The nozzle of the adjustment element (behind the front panel) or
other gas system is blocked.
►
Have the gas system cleaned by an expert.
Deflagration or bubbling / popping noises
Flashback caused by blockages on the burner.
►
Close the gas cylinder valve immediately. Wait 5 minutes and
then start operating the barbecue again. If the fault persists,
clean the burners in the manner described in the “Cleaning
and Maintenance” chapter – “Cleaning Gas-Carrying Compo-
nents (If Necessary)”. Otherwise have the gas system cleaned
by an expert.
Strong Flare Up
The food being cooked is fatty.
►
Remove large amounts of fat, place the meat on a grill tray
or reduce the barbecue temperature.
The barbecue is dirty.
►
Clean the barbecue (see the “Cleaning and Maintenance”
chapter).
DISPOSAL
To dispose of the barbecue, dismantle it into its individual parts
and recycle any metals and plastic.
Dispose of the packaging material in an environmentally
friendly manner so that it can be recycled.
EC DECLARATION OF CONFORMITY
We, the company LANDMANN Germany GmbH, hereby declare
that the gas device described here conforms to the Regulation
(EU) 2016/426
.
The conformity was confirmed by a type test in accordance with
the standards
EN 498:2012
and
EN 484:2019+AC:2020.
The type test was carried out by the notified body
DBI Certification A/S (2531).
Device identification number:
2531CU-0057