ASSEMBLING YOUR L&L EASY-FIRE KILN
easy-fire-install.pdf
3/1/2007 Rev 1.3
Page 10
2007
L&L Kiln Mfg, Inc. 505 Sharptown Rd, Swedesboro NJ 08085 P:856.294.0077 F:856.294.0070 [email protected] hotkilns.com
3) Gently push the right hand side of the element box
away from the kiln sections . This will give you access
to pull the element and thermocouple connection
wires through the element box .
The Element Terminal Box swings over to the left
side exposing the wires :
4) Pull the power and thermocouple wires out .
Pulling the wires out from the back of the
terminal box:
5) Gently lift the element box up and remove from the
kiln sections .
Removing the Terminal Box form the kiln:
6) You are now ready to set up the kiln .
LOCATING THE KILN
1) Place the stand on the floor in the desired location .
This should be set so that the outside stainless steel
surface of the kiln will be at least 12” to 18” from any
combustible wall . Floor must be nonflammable .
Information concerning clearances, ventila-
tion and electrical requirements is detailed in
the INSTALLATION Section of this manual .
Read now if you are uncertain about any of
these issues . DON’T PROCEED UNTIL YOU
ARE COMFORTABLE WITH THE LOCATION
2) Place bottom floor section of kiln on the steel stand
making certain it is centered properly .
3) Note that the kiln bottom is packed on top of the kiln
- so it is easily removed first without moving the kiln .
ASSEMBLING YOUR L&L EASY-FIRE KILN