TROUBLE SHOOTING
LOST OF SUCTION IN DUST COLLECTION
1.
Dust drawer may be full. Empty it.
2.
Blower fan may be clogged. Clean it.
3.
Sander too close to the back wall. Your Sander should be 6”
distance from the wall.
BELT CREEPS
1.
Belt worn out or frayed one side. Install new belt.
MOTOR STOPS WITH SWITCH ON
CAUTION:
TURN SWITCH OFF IMMEDIATELY
1.
Too much equipment operated on same circuit on which Landis S-500 Sander is
connected. Check circuit breaker or fuse box.
2.
An overload may have caused the thermal overload protector in motor to shut off
current. Be sure sander is off, then find and eliminate cause for overload. Motors are
equipped with manual Re-Set thermal overload protector wait at least 15 minutes, then
firmly press Re-Set button on motor with eraser end of pencil or a small blunt dowel.
After approximately 30 minutes you should be able to hear or feel overload protector
click in when pushed to reset. After Re-Set clicks in, turn switch on and motor should run
normally.
SANDING BELT 4” DOESN’T STAY ON THE FELT OR RUBBER WHEEL
1.
Pull or push the release tension arm to put at the right
place.
2.
Secondly verify if there is dirt or dust clogged on the front wheel.
If so, clean it with a scraper or a sandpaper.
3.
Check on the back of the machine is the spring is giving enough
tension to the idler wheel.