![Landis+Gyr 3 SMETS2 Скачать руководство пользователя страница 90](http://html1.mh-extra.com/html/landis-gyr/3-smets2/3-smets2_user-manual_673710090.webp)
90/143
Issue 1.2
Credit mode
© Gyr
D000058620 en a
– E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
Tariff TOU registers
1 - 48
Tariff TOU block
registers
A
A
A
A
last
A
A
A
A
last
To Total active import display
Tariff block
counters
A
A
A
A
last
Tariff display
list
Press button briefly (t < 2 s)
Press button longer (t
≥ 2 s)
30 second timeout from last button press
–
returns display to Total active import display
Figure 23 Tariff display list
14.6 PIN entry
If PIN entry has been enabled, then after selecting the A button on the all
segment display the user is taken to the PIN entry screen
From the PIN entry screen the user is required to enter a pre-entered 4-
digit code.
The pin is entered using the A and B buttons
The A button is used to increment the numbers through 0-9
The B button moves to the next digit
Holding the B button for 1s offers the entered PIN details to the meter
After 3 seconds if a valid Pin entry has been accepted by the meter, then
the user can access the protected displays of the meter.
If an invalid PIN has been entered the user must repeat the sequence
detailed above.