Configuration
Issue 1.2
67/143
D000058620 en a
– E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
© Gyr
Configuration
item
Description
Default
configuration
Unit / Type
Remotely
configurable
via DCC
Billing Calendar Settings
Billing
Calendar
The date-time of the first billing
calendar snapshot and the
periodicity of following ones after
that (where periodicity can be
1=daily; 2=weekly and 3=monthly)
midnight on
first day of
each month
"Start
date Time/
Periodicity
(1=daily,2=weekly,
3=monthly)
Yes
Load Limit Settings
Load Limit
Period
The length of time in seconds which
the Active Power Import needs to
continuously exceed the Load Limit
Power Threshold before a load
limiting event is deemed to have
occurred
30
seconds
Yes
Load Limit
Power
Threshold
the Active Power threshold in kW
above which the measurement of a
load Limit Period is commenced
1000
kW
Yes
Load Limit
Restoration
Period
The length of time in seconds after
the Supply has been Armed
following a Load Limiting Event
before the supply is Enabled by the
meter
31536000
Seconds
Yes
Load Limit
Supply State
The setting which controls the state
of the Supply in the case of load
limiting occurring, being Disabled or
unchanged
unchanged
disabled/
unchanged
Yes
Alert Settings
Alerts
Configuration
Settings
Settings to control whether to
generate and send an alert when
certain events occur in the meter.
NOTE: See separate Events and
Alerts section.
By default, all
mandatory
alerts
designated by
GBCS to be
"always on"
are enabled,
all other alerts
switched off.
Alerts
Configuration
Settings
Yes
Network Settings
Average RMS
Over Voltage
Threshold
The average RMS voltage above
which an over voltage condition is
reported.
258
Volts
Yes
Average RMS
Under Voltage
Threshold
The average RMS voltage below
which an under-voltage condition is
reported.
212
Volts
Yes
Average RMS
Voltage
Measurement
Period
The length of time in seconds over
which the RMS voltage is averaged
1800
Seconds
Yes
RMS Extreme
Over Voltage
Measurement
Period
The duration in seconds used to
measure an extreme over voltage
condition.
180
Seconds
Yes