Elevation Motor
Repair Procedures
83
Figure 7-16.
Elevation Motor Parts (upright removed to improve clarity)
6. Remove the hitch pin from the pin.
7. Remove the pin from the Clevis mount.
8. Remove Elevation Motor.
9. Install new Elevation Motor.
10. Remove the support from beneath the treadmill and set it on the ground.
11. Align the Elevation Motor with the Clevis mount and install the 3/8” diameter mounting pin.
12. Insert the hitch pin.
13. Reconnect the Elevation Motor wires.
14. Enter diagnostic mode as outlined in “Entering Diagnostic Mode” on page
39. Press the UP key briefly and then
hold the DOWN key until the motor stops.
Note:
This process sets the elevation lower limit switch and MUST be done to obtain maximum elevation range.
15. Hold the ¾” diameter elevation screw to prevent it from turning and turn the elevation nut to line it up with the
holes on the elevation assembly.
Note:
Elevation nut must be flush with the end of the elevation shaft.
See Figure 7-17.
Screw
Pin
Hitch pin
Pin
Motor
Clevis
mount