Repair Procedures
Motor Control PCB
76
7.10. Motor Control PCB
Note:
This applies to PWM and SCR Motor Control PCBs (MCBs).
Note:
Cut plastic wire ties as needed but remember to replace them when done!
1. Unplug the treadmill from its outlet.
2. Remove the motor cover.
3. Disconnect all wires from the MCB.
Figure 7-13.
Motor Control PCB and Bracket Removal
4. Reverse to install new MCB.
5. Connect the wires to the MCB as appropriate:
• PWM MCB: see Table 7-2.
• SCR MCB: see Table 7-3.
Table
7-2
PWM MCB Connections
Contact/Connector
Destination
HOT and NEUT terminals
Line cord
JX
Speed sensor connector
JY
Upper harness connector
A-
White wire to Drive Motor
A+
Black wire to Drive Motor
Motor Control
PCB and bracket