Spray Nozzles

Each machine is equipped with one or more spray 
nozzles, depending on the model. Different spray 
nozzles are calibrated for each machine, depending on 
the flow and pressure of that particular model. Spray 
nozzles vary in bore size and angle of spray. Popular 
spray angles are 0°, 15°, 25°, 40°. When ordering, 
please specify size and angle of nozzle. Nozzle size for 
each machine is located on the serial plate.

Unloader Valves

Unloader valves relieve pressure in the line when a 
spray gun is closed. Unloader valves are preset and 
tested at the factory before shipping. Occasional 
adjustment of the unloader may be necessary to 
maintain correct pressure. For valve adjustment 
contact your nearest dealer or call technical support. 
Tampering with the factory setting may cause personal 
injury and/or property damage, and will void the manu-
facturer's warranty.

Winterizing Procedure

Damage due to freezing is not covered by warranty. 
Adhere to the following cold weather procedures 
whenever the washer must be stored or operated 
outdoors under freezing conditions.

It is necessary to protect your machine against freezing 
when temperatures drop below 32° F. Siphoning a 
small amount of antifreeze into the system is recom-
mended. This is done by pouring a 50-50 mix of anti-
freeze and water into the float tank and then siphoning 
100% antifreeze through the detergent line with the 
pump on. If compressed air is available, an air fitting 
can be screwed into the float tank strainer fitting, and by 
injecting compressed air, all water will be blown out of 
the system. The use of a draft diverter will prevent the 
wind chill factor from freezing the coil.

Low Pressure Diagnosis

(Machines with spray gun)

Refer to Troubleshooting Chart for low pressure. If the 
trouble is found to be either the unloader or the pump, 
your next step is to determine which is the problem. 
This can be done by eliminating the unloader from the 
system and attaching the 50' discharge hose directly to 
the pump. If high pressure is developed in this manner, 
the pump is good and the unloader needs to be 
repaired or replaced. If low pressure is still present, 
then the pump needs repairing. 

CAUTION: When using this procedure to test 
components keep the spray gun open at all times.

ATTENTION: Lorsque cette procédure est utilisée 

pour tester les composants, garder le pistolet 
pulvérisateur ouvert en tout temps.

High Limit Hot Water Thermostat

For safety, each machine is equipped with a high limit 
control switch. In the event the temperature of the water 
should exceed its operating temperature, the high limit 
control will turn the burner off until the water cools.

Pumps

Use only SAE 10W-40 weight non-foaming oil. Change 
oil after first 50 hours of use. Thereafter, change oil 
every year or at 500 hour intervals. Oil level should be 
checked through use of the dipstick found on the top of 
the pump or by the red dot visible through the oil gauge 
window. Oil should be maintained at that level.

Heating Coils
To Check Water Heater Coil for Leaks

With the main burners “OFF” start the pumping unit and 
allow it to run for a few minutes. Check into the burner 
compartment with a drop light or flashlight. If no leaks 
are visible, then water dripping from coils is condensa-
tion from the flue gases when the burners are on.

Condensation from Heating Coil

When cold water is being pumped into the water heater 
coils, and the burners are on, condensation will form on 
the coils and drip down into the burner compartment, 
giving the appearance of a leaking coil, particularly on 
cold humid days.

Descaling Coils

In alkaline water areas, lime deposits can accumulate 
rapidly inside the coil pipes. This growth is increased by 
the extreme heat build up in the coil. The best preven-
tion for liming conditions is to use high quality cleaning 
detergents. In areas where alkaline water is an extreme 
problem, periodic use of Landa Coil Descaler (part # 
8.914-296.0) will remove lime and other deposits 
before coil becomes plugged. (

Periodic descaling of the heating coil is recom-
mended so please consult your local Landa Dealer 
for instructions.

Landa VHG Operator’s Manual  8.913-952.0 - BR

Содержание VHG

Страница 1: ...8 913 952 0 BR 08 21 20 VHG Hot Water Electric Powered Natural Gas or LP Heated Operator s Manual Pressure Washer MODELS VHG4 3000 VHG4 2000 VHG4 2200 VHG5 3000 VHG6 3000 VHG8 3000...

Страница 2: ...2 Landa VHG Operator s Manual 8 913 952 0 BR...

Страница 3: ...Hot Water Thermostat 24 Pumps 24 Heating Coils 24 Gas Valve Regulator Adjustment 25 Pressure Relief Valve 25 Propane Gas 25 Burner Features 26 Basic Facts 27 Smart Relay Instructions 28 Factory Set P...

Страница 4: ...in tenance to keep the machine and its components in good working condition They are listed in this general order Spray Nozzles Unloader Valves Winterizing Procedure Low Pressure Diagnosis High Limit...

Страница 5: ...perty damage personal injury or loss of life AVERTISSEMENT Si ces directives ne sont pas suivies la lettre un incendie ou une explosion pourrait survenir et entra ner des dommages la propri t des l si...

Страница 6: ...liquides inflammables WARNING Risk of fire Do not change LP tanks when the product is operating or still hot AVERTISSEMENT Risque d incendie Ne pas changer les r servoirs de p trole liquide pendant q...

Страница 7: ...in a well ventilated area DANGER Risque d asphyxie Utiliser ce produit uniquement dans un endroit bien ventil 14 Avoid installing machines in small areas or near exhaust fans Adequate oxygen is neede...

Страница 8: ...When tightening the POL Nut left hand thread on the service valve draw it up snug with a proper wrench This is a machined male brass fitting which seats securely against a female seat in the POL valve...

Страница 9: ...sure Hose Connect one end to water pump high pressure discharge nipple and the other end to spray gun Rupture Disk Secondary pressure release in the unlikely event the unloader valve fails Not Shown U...

Страница 10: ...10 Installation VHG 4 5 Landa VHG Operator s Manual 8 913 952 0 BR...

Страница 11: ...11 Installation VHG 6 8 Landa VHG Operator s Manual 8 913 952 0 BR...

Страница 12: ...t away Allow enough space for servicing the machine Local code will require certain distances from floor and walls Two feet away should be ade quate WARNING Avoid small areas or near exhaust fans AVER...

Страница 13: ...reprise oeuvrant dans le domaine du propane Most LP gas pressure washer heaters are designed to operate on LP gas vapor only Therefore all LP gas containers designed for vapor service must be trans po...

Страница 14: ...ouble wall type Sometimes vents have to be built of such great length that they come apart at their joints under their own weight These should be screwed together at the joints with sheet metal screws...

Страница 15: ...anufacturer and not a licensed contractor and as such we are unable to make recom mendations for suitable make and model of power vents and compliance with local building codes Damper An exhaust stack...

Страница 16: ...3 Open the damper to the fully open position 4 Start the pressure washer and allow it to heat up for at least 20 minutes before making any adjust ments 5 Note the values for Excess Air and or Oxygen...

Страница 17: ...ne pourrait causer des dommages mat riels ou des blessures corporelles 1 Installation or servicing of gas appliances and controls must only be performed by qualified personnel After installation or se...

Страница 18: ...ally grounded Is there ample water supply Have all flammable liquids or gases been removed from installation location Is there adequate gas supply for the BTU rating of the burner Is incoming gas supp...

Страница 19: ...ssembly to union on machine and plug in wires STEP 2 Connect the high pressure hose to the discharge fitting Push coupler collar forward until secure STEP 5 Before installing nozzle turn on the water...

Страница 20: ...ot water push the burner switch to the ON position and pull the trigger on the spray gun Landa VHG Operator s Manual 8 913 952 0 BR Selection of high or low pressure is accompanied by turning the hand...

Страница 21: ...e to the pump Cleaning Tips Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solution and apply to surface For best results limit your work area to secti...

Страница 22: ...detergent valve and spray gun allowing the detergent lines to be flushed and the burner to cool Otherwise coil damage may occur STEP 3 After water has cooled push or turn pump switch to OFF position I...

Страница 23: ...etach water supply hose and high pressure hose 3 Turn on the machine for a few seconds until remaining water exits Turn pump off immediately 4 Do not allow high pressure hose to become kinked 5 Store...

Страница 24: ...tly to the pump If high pressure is developed in this manner the pump is good and the unloader needs to be repaired or replaced If low pressure is still present then the pump needs repairing CAUTION W...

Страница 25: ...rather than rise out of the stack Hence adequate floor space and good ventilation are especially important with propane systems Gas Pressure Requirements All propane fired machines operate on vapor pr...

Страница 26: ...union in main burner line below thermostat Slide burner manifold out through shell opening 2 TO CLEAN BURNER JETS Select proper size drill for type gas involved Use pin vise to hold drill and ream ou...

Страница 27: ...per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Number 125 91 Molecular Weight 44 09 58 12 To Calculate Running Cost...

Страница 28: ...own arrow keys or 8 To set the date repeat steps 6 and 7 9 To accept your entries press OK 10 To go back to the previous menu at anytime press ESC Programming Instructions The 900 1400 can be configur...

Страница 29: ...indow shows the three parame ters See figure 4 NOTE Ta is the accumulator timer and T is the adjustable timer the variable that changes 5 Press OK to change the value of Timer 1 Using the left right a...

Страница 30: ...e Pump On switch Timer 2 30 00 Seconds Pump will run in bypass for 30 seconds before shutting off machine is still in standby mode Pulling the gun trigger will restart the pump Timer 3 15 00 Seconds I...

Страница 31: ...s for 3 minutes and shut off To restart push the Pump On switch Timer 2 01 00 Hours To operate in time delay mode timer 2 must be deactivated This is done by setting timer 2 to value greater than time...

Страница 32: ...lumn 6 35 oz sq in 11 Water Column 4 lb sq in 1 lb sq in 27 71 Water Column 1 lb sq in 14 73 lbs sq in 1 Mercury 39 lb sq in 1 Std Atmosphere 14 73 lbs sq in Date Oil Changed Month Day Year Estimated...

Страница 33: ...er severe conditions Maintenance Schedule Replace Fuel Lines Annually Pump Oil SAE 10W 40 non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually C...

Страница 34: ...iscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent line s Repair hole Strainer basket plugged Remove and clean...

Страница 35: ...g kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with valve kit Obstruction in spray nozzle Remove obstruction Leaking pre...

Страница 36: ...is turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals replace gas valve 3 Probe terminals PV and MV PV If 24 volts...

Страница 37: ...r rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS OFF BEFORE THE BURNER SWITCH OR FLOW SWITCH IS TURNED OFF Draft con...