Combustion and Ventilation Air

Properly sized vents are vital for the safe and efficient 
operation of a pressure washer installed in a confined 
space. When combustion and ventilation air are 
supplied from inside the building, each opening must 
have an area of one square inch for every 1,000 BTUH 
input. When combustion air is supplied from the 
outside, each opening must have an area of one 
square inch for every 2,000 BTUH for horizontal ducts 
and one square inch for every 4,000 BTUH for vertical 
ducts (refer to NFPA 54).

The purpose of venting a gas pressure washer is to 
completely remove all products of combustion and to 
vent gasses to the outside air without condensation in 
the vent or spillage at the draft hood (except in cases of 
downdraft or poor stack conditions). To assure correct 
venting, use a strong, gas-tight insulated pipe with a 
cross section equal to that of the flue collar or draft 
hood outlet and of sufficient vertical height.

During vent installation, avoid sharp turns, long hori-
zontal runs and improper pitches. Maintain proper 
support of vent connectors and joints, observe clear-
ances from all combustibles and top the vent outlet with 
an approved cap.

Type "B", due to its temperature rating, can only be 
used with natural draft pressure washers. A "B" vent is 
designed for exhaust temperatures not to exceed 
470°F (245°C).

All venting installations must conform to local codes. In 
the absence of local codes, refer to "National Fuel Gas 
Code" NFPA 54 and be constructed of materials 
approved by the Uniform Building Code.

Vents penetrating ceilings or walls should be double-
wall approved appliance vents and should be one to 
two inches from combustibles. Vents passing through 
enclosed spaces and vents exposed to the weather 
should also be the double-wall type. Sometimes vents 
have to be built of such great length that they come 
apart at their joints under their own weight. These 
should be screwed together at the joints with sheet 
metal screws, usually three per joint. If the inspector 
indicates that the vent is too close to combustibles, it 
may be necessary to chisel away some of the combus-
tible or route the vent pipe around the combustible. The 
cross-sectional area of any flue shall not be less that 
the cross-sectional area of the flue vent connection 
outlet of machine.

Water Source

The water source for the machine should be supplied 
by a 5/8" I.D. garden hose with a city water pressure of 
not less than 30 PSI. If the water supply is inadequate, 
or if the garden hose is kinked, the machine will run 
very rough and the burner will not fire.

Water Connection

Connect the high pressure hose by pulling the coupler 
collar back and then inserting it onto the discharge 
nipple. Secure it by pushing the collar forward.

Attach the wand into the spray gun using teflon tape on 
the pipe threads to avoid leaks.

Inspection and Testing Gas Piping

The building structure should not be weakened by 
installing the gas piping. The piping should not be 
supported by other piping, but should be firmly 
supported with gas hooks, straps, bands or hangers. 
Butt or lap welded pipe should not be run through or in 
an air duct or clothes chute.

Before turning gas under pressure into piping, all 
openings from which gas can escape should be closed. 
Immediately after turning on gas, the system should be 
checked for leaks. This can be done by watching the 
1/2 cubic foot test dial for 5 minutes for any movement 
or by soaping each pipe connection and watching for 
bubbles. If a leak is found, make the necessary repairs 
and repeat the above test.

Defective pipes or fittings should be replaced and not 
repaired. Never use a flame or fire in any form to locate 
gas leaks — use a soap solution.

Landa VHG Operator’s Manual  8.913-952.0 - BR

Содержание VHG

Страница 1: ...8 913 952 0 BR 08 21 20 VHG Hot Water Electric Powered Natural Gas or LP Heated Operator s Manual Pressure Washer MODELS VHG4 3000 VHG4 2000 VHG4 2200 VHG5 3000 VHG6 3000 VHG8 3000...

Страница 2: ...2 Landa VHG Operator s Manual 8 913 952 0 BR...

Страница 3: ...Hot Water Thermostat 24 Pumps 24 Heating Coils 24 Gas Valve Regulator Adjustment 25 Pressure Relief Valve 25 Propane Gas 25 Burner Features 26 Basic Facts 27 Smart Relay Instructions 28 Factory Set P...

Страница 4: ...in tenance to keep the machine and its components in good working condition They are listed in this general order Spray Nozzles Unloader Valves Winterizing Procedure Low Pressure Diagnosis High Limit...

Страница 5: ...perty damage personal injury or loss of life AVERTISSEMENT Si ces directives ne sont pas suivies la lettre un incendie ou une explosion pourrait survenir et entra ner des dommages la propri t des l si...

Страница 6: ...liquides inflammables WARNING Risk of fire Do not change LP tanks when the product is operating or still hot AVERTISSEMENT Risque d incendie Ne pas changer les r servoirs de p trole liquide pendant q...

Страница 7: ...in a well ventilated area DANGER Risque d asphyxie Utiliser ce produit uniquement dans un endroit bien ventil 14 Avoid installing machines in small areas or near exhaust fans Adequate oxygen is neede...

Страница 8: ...When tightening the POL Nut left hand thread on the service valve draw it up snug with a proper wrench This is a machined male brass fitting which seats securely against a female seat in the POL valve...

Страница 9: ...sure Hose Connect one end to water pump high pressure discharge nipple and the other end to spray gun Rupture Disk Secondary pressure release in the unlikely event the unloader valve fails Not Shown U...

Страница 10: ...10 Installation VHG 4 5 Landa VHG Operator s Manual 8 913 952 0 BR...

Страница 11: ...11 Installation VHG 6 8 Landa VHG Operator s Manual 8 913 952 0 BR...

Страница 12: ...t away Allow enough space for servicing the machine Local code will require certain distances from floor and walls Two feet away should be ade quate WARNING Avoid small areas or near exhaust fans AVER...

Страница 13: ...reprise oeuvrant dans le domaine du propane Most LP gas pressure washer heaters are designed to operate on LP gas vapor only Therefore all LP gas containers designed for vapor service must be trans po...

Страница 14: ...ouble wall type Sometimes vents have to be built of such great length that they come apart at their joints under their own weight These should be screwed together at the joints with sheet metal screws...

Страница 15: ...anufacturer and not a licensed contractor and as such we are unable to make recom mendations for suitable make and model of power vents and compliance with local building codes Damper An exhaust stack...

Страница 16: ...3 Open the damper to the fully open position 4 Start the pressure washer and allow it to heat up for at least 20 minutes before making any adjust ments 5 Note the values for Excess Air and or Oxygen...

Страница 17: ...ne pourrait causer des dommages mat riels ou des blessures corporelles 1 Installation or servicing of gas appliances and controls must only be performed by qualified personnel After installation or se...

Страница 18: ...ally grounded Is there ample water supply Have all flammable liquids or gases been removed from installation location Is there adequate gas supply for the BTU rating of the burner Is incoming gas supp...

Страница 19: ...ssembly to union on machine and plug in wires STEP 2 Connect the high pressure hose to the discharge fitting Push coupler collar forward until secure STEP 5 Before installing nozzle turn on the water...

Страница 20: ...ot water push the burner switch to the ON position and pull the trigger on the spray gun Landa VHG Operator s Manual 8 913 952 0 BR Selection of high or low pressure is accompanied by turning the hand...

Страница 21: ...e to the pump Cleaning Tips Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solution and apply to surface For best results limit your work area to secti...

Страница 22: ...detergent valve and spray gun allowing the detergent lines to be flushed and the burner to cool Otherwise coil damage may occur STEP 3 After water has cooled push or turn pump switch to OFF position I...

Страница 23: ...etach water supply hose and high pressure hose 3 Turn on the machine for a few seconds until remaining water exits Turn pump off immediately 4 Do not allow high pressure hose to become kinked 5 Store...

Страница 24: ...tly to the pump If high pressure is developed in this manner the pump is good and the unloader needs to be repaired or replaced If low pressure is still present then the pump needs repairing CAUTION W...

Страница 25: ...rather than rise out of the stack Hence adequate floor space and good ventilation are especially important with propane systems Gas Pressure Requirements All propane fired machines operate on vapor pr...

Страница 26: ...union in main burner line below thermostat Slide burner manifold out through shell opening 2 TO CLEAN BURNER JETS Select proper size drill for type gas involved Use pin vise to hold drill and ream ou...

Страница 27: ...per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Number 125 91 Molecular Weight 44 09 58 12 To Calculate Running Cost...

Страница 28: ...own arrow keys or 8 To set the date repeat steps 6 and 7 9 To accept your entries press OK 10 To go back to the previous menu at anytime press ESC Programming Instructions The 900 1400 can be configur...

Страница 29: ...indow shows the three parame ters See figure 4 NOTE Ta is the accumulator timer and T is the adjustable timer the variable that changes 5 Press OK to change the value of Timer 1 Using the left right a...

Страница 30: ...e Pump On switch Timer 2 30 00 Seconds Pump will run in bypass for 30 seconds before shutting off machine is still in standby mode Pulling the gun trigger will restart the pump Timer 3 15 00 Seconds I...

Страница 31: ...s for 3 minutes and shut off To restart push the Pump On switch Timer 2 01 00 Hours To operate in time delay mode timer 2 must be deactivated This is done by setting timer 2 to value greater than time...

Страница 32: ...lumn 6 35 oz sq in 11 Water Column 4 lb sq in 1 lb sq in 27 71 Water Column 1 lb sq in 14 73 lbs sq in 1 Mercury 39 lb sq in 1 Std Atmosphere 14 73 lbs sq in Date Oil Changed Month Day Year Estimated...

Страница 33: ...er severe conditions Maintenance Schedule Replace Fuel Lines Annually Pump Oil SAE 10W 40 non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually C...

Страница 34: ...iscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent line s Repair hole Strainer basket plugged Remove and clean...

Страница 35: ...g kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with valve kit Obstruction in spray nozzle Remove obstruction Leaking pre...

Страница 36: ...is turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals replace gas valve 3 Probe terminals PV and MV PV If 24 volts...

Страница 37: ...r rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS OFF BEFORE THE BURNER SWITCH OR FLOW SWITCH IS TURNED OFF Draft con...