manualshive.com logo in svg
background image

4

How To Use This Manual

This manual contains the following sections:

How to Use This Manual

Safety

Operations

Maintenance

Parts List

The HOW TO USE THIS MANUAL section will tell you 

how to find important information for ordering correct 

repair parts.
Parts may be ordered from authorized dealers. When 

placing an order for parts, the machine model and 

machine serial number are important. Refer to the 

MACHINE DATA box which is filled out during the 

installation of your machine. The MACHINE DATA box 

is located on the inside of the front cover of this manual. 

The model and serial number of your machine is 

located on the back of the machine.

The SAFETY section contains important information 

regarding hazardous or unsafe practices of the 

machine. Levels of hazards are identified that could 

result in product damage, personal injury, or severe 

injury resulting in death.
The OPERATIONS section is to familiarize the operator 

with the operation and function of the machine.
The MAINTENANCE section contains preventive main

-

tenance to keep the machine and its components in 

good working condition. They are listed in this general 

order:

Winterizing Procedure

High Limit Hot Water Thermostat

Heating Coils

Gas Valve Regulator

Electrode Adjustment

Pilot Burner Adjustment 

Pressure Relief Valve

Propane Gas (Optional Conversion Kit)

General Safety Precautions

Gas Pressure Requirements

Propane Cylinder Capacity

Burner Features

Burner Troubleshooting

Troubleshooting

The PARTS LIST section contains assembled parts 

illustrations and corresponding parts list. The parts lists 

include a number of columns of information:

REF – 

column refers to the reference number 

on the parts illustration.

PART NO.

 – column lists the part number for 

the part.

QTY

 – column lists the quantity of the part used 

in that area of the machine.

DESCRIPTION 

– column is a brief description 

of the part.

NOTES 

– column for information not noted by 

the other columns.

NOTE: If a service or option kit is installed on your 

machine, be sure to keep the KIT INSTRUCTIONS 

which came with the kit. It contains replacement parts 

numbers needed for ordering future parts.

NOTE: The manual part number is located on the 

lower right corner of the front cover.

Model:

Date of Purchase:

Serial Number:

Dealer:

Address:

Phone Number:

Sales Representative:

Landa NG 3000 Operator’s Manual  8.913-942.0 - E

Содержание NG-3000

Страница 1: ...8 913 942 0 E 08 20 21 NG Hot Water Generator Operator s Manual Heater Module MODELS NG 3000 1 103 901 0 For the Landa Dealer nearest you consult our web page at www landa com...

Страница 2: ...2 Landa NG 3000 Operator s Manual 8 913 942 0 E Machine Data Label...

Страница 3: ...uctions 18 Maintenance Preventative Maintenance 19 Winterizing Procedure 19 High Limit Hot Water Thermostat 19 Heating Coils 19 Gas Valve Regulator 20 Electrode Adjustment 20 Pilot Burner Adjustment 2...

Страница 4: ...ts in good working condition They are listed in this general order Winterizing Procedure High Limit Hot Water Thermostat Heating Coils Gas Valve Regulator Electrode Adjustment Pilot Burner Adjustment...

Страница 5: ...g parts please specify model and serial number Use only identical replacement parts This machine is to be used only by trained operators Important Safety Information NOTE This heater module NG 3000 is...

Страница 6: ...machine with wet hands or while standing in water Always disconnect power before servicing WARNING Flammable liquids can create fumes which can ignite causing property damage or severe injury AVERTISS...

Страница 7: ...ult in injury from a whipping wand AVERTISSEMENT Agripper la lance de nettoyage avec les deux mains avant de commencer Le non respect de cette consigne pourrait mener des blessures caus es par le mouv...

Страница 8: ...ent 22 Never expose a spark or flame where there may be unburned gas present CAUTION This product incorporates parts that produce sparks and therefore when located in a garage it should be in a room o...

Страница 9: ...High Pressure Nozzle not included Electric Cold Water Pressure Washer not included Vent according to local codes not included Burner Switch Spray Gun not included High Pressure Hose Not included Use...

Страница 10: ...officials regarding any specific code or regu lations governing the installation The installation must conform to local codes The gas pressure coming out of the regulator and going to the burner ring...

Страница 11: ...uit Joint compounds pipe dope should be used sparingly on male threads only and be approved for all gases Propane Gas The following pipe and stack sizes are just recommen dations Always consult a loca...

Страница 12: ...rter Input BTU Per Hour Draft Hood Flue Pipe Size 250 000 320 000 8 inch 320 000 410 000 9 inch NOTE If the flue pipe exceeds 10 ft in length or contains more than two elbows use next size larger pipe...

Страница 13: ...nd Testing Gas Piping The building structure should not be weakened by installing the gas piping The piping should not be supported by other piping but should be firmly supported with gas hooks straps...

Страница 14: ...a soap solution With the main burner on coat pipe and tubing joints gaskets etc Bubbles indicate leaks 14 If the machine is installed in an enclosed room care should be taken to ensure that an adequa...

Страница 15: ...Is there ample water supply Have all flammable liquids or gases been removed from installation location Is there adequate gas supply for the BTU rating of the burner Is incoming gas supply pressure to...

Страница 16: ...from Pressure Washer Inlet Connector Control Knob Red Ignitor STEP 5 Depress control knob all the way and hold it in After five 5 seconds depress the red ignitor until you hear a loud click Repeat 3...

Страница 17: ...If painted surfaces are peeling or chipping use extreme caution as pressure washer may remove the loose paint from the surface Keep the spray nozzle a safe distance from the surface you plan to clean...

Страница 18: ...4 Turn water off Drain water from coil to prevent freezing STEP 2 Rinse detergent with fresh water if attached pressure washer is able to apply detergent STEP 3 After water has cooled turn the attache...

Страница 19: ...o the discharge coupling fitting and by injecting compressed air all water will be blown out of the system The use of a draft diverter will prevent the wind chill factor from freezing the coil High Li...

Страница 20: ...ly to prevent blockage Propane Gas Optional Conversion Kit General Safety Precautions Have a qualified gas service person assist in any gas burner installation or service Few maintenance people or mec...

Страница 21: ...nning time desired Burner Features Operated Automatic Valve This machine is equipped with a thermopile self powered combination gas control This system is designed as a constant burning pilot Lighting...

Страница 22: ...follows B Thermopile Output Reading Check B Reading Switch contacts OPEN Main burner OFF If the minimum 250 millivolt reading is not obtainable readjust pilot for maximum millivolt output If millivol...

Страница 23: ...Restricted pilot line or clogged pilot orifice Clean pilot tubing and orifices PILOT LIT BUT MAIN BURNER WON T COME ON Faulty wiring Test wiring Low pilot flame Check inlet pressure pilot orifice pos...

Страница 24: ...24 Notes Landa NG 3000 Operator s Manual 8 913 942 0 E...

Страница 25: ...25 Parts Parts LANDA NG 3000 Landa NG 3000 Operator s Manual 8 913 942 0 E...

Страница 26: ...913 942 0 E 35 41 37 25 36 33 34 14 28 27 26 42 47 50 62 63 30 49 32 48 31 29 30 68 16 3 4 5 10 9 7 6 2 8 38 13 40 37 21 60 52 15 19 71 20 53 37 25 36 44 50 22 17 18 72 11 12 39 53 37 69 43 51 66 67 2...

Страница 27: ...18 9 802 678 0 1 IGNITOR PIEZO 19 8 719 968 0 1 HOLDER WAND ZINC PLATED 20 9 802 807 0 9 WASHER 3 8 SAE FLAT 21 9 802 779 0 8 NUT 3 8 ESNA 22 9 800 031 0 1 LABEL PILOT LIGHT WARNING 23 8 706 236 0 1...

Страница 28: ...EL MANUFACTURER S CLEANING SOLUTION 56 9 800 021 0 1 LABEL HOT WATER OUTLET 57 9 803 563 0 1 CONNECTOR 1 4 TUBE X 1 8 MPT 58 8 706 910 0 1 BUSHING 1 4 X 1 8 PIPE 59 9 802 682 0 1 TAB GROUND 60 9 802 7...

Страница 29: ...29 Landa NG 3000 Operator s Manual 8 913 942 0 E Notes...

Страница 30: ...8 913 942 0 Printed in U S A...

Отзывы: