11
Operations
Union Location
A 1/8" N.P.T. plugged tapping accessible for test gauge
connection shall be installed immediately upstream of
the gas supply connection for the purpose of deter
-
mining gas supply pressure to the burner, and to
prevent damage to gas valve.
If a manual gas shut off valve is not in the gas supply
line within six feet of the machine and in an accessible
location, one shall be installed.
A manual shut-off valve shall be installed in the gas
supply line external to the appliance. See Figure 2. The
gas line should be a separate supply direct from the
meter to the burner. It is recommended that new pipe
be used and located so that a minimum amount of work
will be required in future servicing. The piping should be
so installed as to be durable, substantial and gas tight.
It should be clear and free from cutting burrs and
defects in structure of threading. Cast iron fittings or
aluminum tubing should not be used for the main gas
circuit. Joint compounds (pipe dope) should be used
sparingly on male threads only and be approved for all
gases.
Propane Gas
The following pipe and stack sizes are just recommen
-
dations. Always consult a local plumber and venting
contractor for local codes and regulations during instal
-
lation.
The following tables are maximum capacity of final
stage pipe in thousands of Btu/hr of commercial
propane
From first stage regulator (at tank) to second stage
regulator
The chart below is based on incoming gas pressure of
10 PSI and a pressure drop of 1 PSI. Numbers are for
straight schedule 40 pipe; fittings further reduce
capacity.
Length of Pipe
(ft.)
Iron Pipe Size
1/2"
3/4"
10
3339
6982
20
2295
4799
30
1843
3854
40
1577
3298
50
1398
2923
60
1267
2649
70
1165
2437
80
1084
2267
90
1017
2127
100
961
2009
150
772
1613
200
660
1381
250
585
1224
300
530
1109
350
488
1020
400
454
949
450
426
890
500
402
841
Landa NG 3000 Operator’s Manual 8.913-942.0 - E
Location of union and drip
leg for connecting conversion
burner to house piping
Floor Level
1/8 in. N.P.T. Plugged
Pressure Gauge Port
Flow
Union
Control Manifold
Manual
Shut-off
Valve
Tee
3 in. (76.2 mm)
MINIMUM
Pipe Cap
Содержание NG-3000
Страница 2: ...2 Landa NG 3000 Operator s Manual 8 913 942 0 E Machine Data Label...
Страница 24: ...24 Notes Landa NG 3000 Operator s Manual 8 913 942 0 E...
Страница 25: ...25 Parts Parts LANDA NG 3000 Landa NG 3000 Operator s Manual 8 913 942 0 E...
Страница 29: ...29 Landa NG 3000 Operator s Manual 8 913 942 0 E Notes...
Страница 30: ...8 913 942 0 Printed in U S A...