Return of Damaged Goods

IMPORTANT  If any item has been damaged in transit, this should be reported to the carrier and to the 

supplier immediately.  Damage caused in transit is the responsibility of the carrier not the supplier.

DO NOT RETURN a damaged instrument to the sender as the carrier will not then consider a claim.  Save 

the packing with the damaged article for inspection by the carrier.

Return of Goods for Repair

If you need to return goods for repair please contact our Customer Service Department.  They will be 

able to advise you on the correct returns procedure.

Any item returned to Land Instruments International should be adequately packaged to prevent damage 

during  transit.

You must include a written report of the problem together with your own name and contact information, 

address, telephone number, email address etc.

Design and Manufacturing Standards

The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for 

the design, manufacture and on-site servicing of combustion, environmental monitoring and non-contact 

temperature measuring instrumentation.  

Approvals apply in the USA

This instrument complies with current European directives relating to Electromagnetic 

Compatibility 89/336/EEC and Low Voltage Directive 73/23/EEC.

Operation of radio transmitters, telephones or other electrical/electronic devices in close proximity 

to the equipment while the enclosure doors of the instrument or its peripherals are open, may cause 

interference and possible failure where the radiated emissions exceed the EMC directive.

The protection provided by both CE and IP classifications to this product may be invalidated if alterations 

or additions are made to the structural, electrical, mechanical or pneumatic parts of this system. Such 

changes may also invalidate the standard terms of warranty.

Copyright

This manual is provided as an aid to owners of Land Instruments International’s products and contains 

information proprietary to Land Instruments International.  This manual may not, in whole or part, be 

copied, or reproduced without the expressed written consent of Land Instruments International Ltd.

Copyright © 2012 Land Instruments International.

Содержание Cyclops 160B

Страница 1: ...Cyclops 160B Land Instruments International 2007 2012 User Guide Issue 2 January 2012 Publication N 806458 Language English...

Страница 2: ...n It is possible that this equipment is to be installed on or near to machinery or equipment operating at high temperatures and high pressures Suitable protective clothing along with face and eye prot...

Страница 3: ...s etc Design and Manufacturing Standards The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion en...

Страница 4: ...Cyclops 160B User Guide...

Страница 5: ...Operational Trigger Modes 21 9 Thermometer Operation 24 10 Bluetooth wireless communication 28 11 Emissivity 29 12 Maintenance 33 13 Accessories and Spare Parts 34 14 User Configuration Record 37 App...

Страница 6: ...Cyclops 160B User Guide Fig 1 1 Land Cyclops 160B portable infrared thermometer...

Страница 7: ...d to measure and display temperatures in the range 200 to 1400 C 392 to 2552 F The thermometer can also measure and display these temperatures in Kelvin and Rankine The target temperature is measured...

Страница 8: ...receipt of the instrument make a note of the Instrument Type and Serial Number in the spaces provided below Instrument Type Serial Number Fig 1 2 Land Cyclops 160B portable thermometer nomenclature A...

Страница 9: ...close up lens Detector InGaAs photocell Spectral response nominally 1 6 m Emissivity adjustment 0 10 to 1 20 in 0 01 steps Response time digital display update 0 5 seconds approx peak and valley opera...

Страница 10: ...switch 2 position 2 Keypad 8 Tripod mounting hole 3 Optical focusing ring 9 Adjustable wrist strap in packaging 4 Protective window 10 Adjustable eyepiece 5 Lens cap 11 Battery compartment cover 6 ON...

Страница 11: ...g 4 3 5 Insert the battery ensuring that the contact springs engage centrally into the battery terminals Slide the battery cover back into place and ensure that the cover catch engages with the thermo...

Страница 12: ...as the following power saving features If the thermometer is in Menu Mode for over one minute without any key being pressed the display returns to Measure Mode If the thermometer is in Measure Mode fo...

Страница 13: ...des the trigger activates advanced functions within the thermometer see Section 8 5 3 LCD Display Panel Keypad The LCD display panel d is on the left hand side of the thermometer body see Fig 3 1 item...

Страница 14: ...The Optical Focus Ring f is on the lens assembly at the front of the thermometer see Fig 3 item 3 The focus ring allows you to manually adjust the lens assembly and sharpen the scene in view A protect...

Страница 15: ...sion reflex optical system gives a narrow field of view 180 1 to 98 energy As the instrument is focusable you can calculate an approximate target size from the information given in Fig 6 1 Target dist...

Страница 16: ...p lens to the Cyclops 160B thermometer unscrew the clear protection window from the lens assembly and replace it with the relevant close up lens The optical transmission characteristics of the protect...

Страница 17: ...ch each user s eyesight characteristics 1 Use the viewfinder to view a plain brightly lit background such as a blank wall 2 Rotate the rubber eye cup to bring the graticule circle to the sharpest poss...

Страница 18: ...ar the bottom of the screen For a list of error codes and their meanings see Appendix 2 7 2 Measure Mode When the unit is in Measure Mode the display indicates the Peak Continuous Average and Valley t...

Страница 19: ...e value held on display d New Peak temperature value reached display updated e Object temperature falls last Peak temperature value held on display f Trigger released last Peak temperature value froze...

Страница 20: ...selected the temperature reading closely matches the object temperature Only the most rapid fluctuations in the input are smoothed in the output With a Slow time constant selected the temperature rea...

Страница 21: ...antaneous temperature value and is held on display with rise in object temperature c Object temperature falls new Valley temperature value reached display updated as object temperature falls Object te...

Страница 22: ...s the key When a main menu option is selected the available sub options are displayed 4 Use the and keys to highlight the required sub option in the menu Press the key to select it 5 For sub options w...

Страница 23: ...the emissivity value can be set Use the and keys to enter the required value For information on emissivity values see Section 11 Emissivity The default value is 1 00 c d e Alarms The alarms function a...

Страница 24: ...ermometer is inactive The default setting is Off Note Use of the backlight will reduce the life of the battery It is recommended that the backlight is switched off when not required s t Sounder This o...

Страница 25: ...indow compensation On and an external viewing window value to be determined practically into the customer process w About This function w accesses general information about the product The details dis...

Страница 26: ...Cyclops 160B User Guide Page 20 Fig 7 6 Cyclops 160B icon navigational flow chart...

Страница 27: ...ng the two stage trigger functions 8 2 Classic Mode Classic Mode is the simplest operating mode and the one that most closely resembles the operation of earlier Cyclops portable thermometers In Classi...

Страница 28: ...ger was pressed to the T1 position The emissivity set point and window compensation indicator value in use are also output as part of the data packet The temperature components of this data packet are...

Страница 29: ...ayed internally within the viewfinder When the trigger is pulled to the T2 position live temperature data only is streamed at the maximum collection rate approximately 33 readings per second to the Bl...

Страница 30: ...User Interface Setup Measurement Setup The following list details the setup groups and the available selections Setup Group Function Selection Options Data Output Setup Trigger Mode Classic History Bu...

Страница 31: ...the information in Section 11 5 Ensure that Window Compensation is Off 6 Ensure that the Alarms function is set to Off 7 Ensure the Bluetooth option is set to Off 8 On the side display select the Con...

Страница 32: ...battery status ensure that there is sufficient battery life remaining 2 Go into Menu Mode open the Trigger Mode menu and select Classic Mode 3 Enter the Emissivity value for the material under observ...

Страница 33: ...chosen viewing window port material e g 0 880 9 Select the Continuous temperature measurement option 10 Aim the thermometer through the viewing window port at the target and focus the graticule onto...

Страница 34: ...re that the datalogging software has been loaded to the PC laptop or Pocket PC see DL 1000 v2 User Guide as required 2 Establish Bluetooth communications from the Cyclops 160B to a laptop PC Pocket PC...

Страница 35: ...target is outside the thermometer s measurement span or that the emissivity value cannot be accurately specified and should be determined in situ See Section 11 2 If you have a query regarding the em...

Страница 36: ...0 65 Copper 0 05 Oxidised 0 85 Gold 0 02 Iron Steel 0 30 Oxidised 0 85 Lead 0 28 Oxidised 0 65 Magnesium 0 24 Oxidised 0 75 Molybdenum 0 25 Oxidised 0 80 Nickel 0 25 Oxidised 0 85 Palladium 0 23 Plat...

Страница 37: ...laneous Material Cyclops 160B Asbestos Board paper cloth 0 90 Asphalt 0 85 Carbon Graphite 0 85 Soot 0 95 Cement Concrete 0 70 Cloth All types close weave 0 80 Open weave reduces emissivity Glass 3mm...

Страница 38: ...e or reference instrument measure the temperature at the target location 3 Press the Select key to go into the Menu mode press the Down arrow key to select the e setting and press the Select key to se...

Страница 39: ...ly eyepiece and display panel are kept clean and free from contaminants On a regular basis clean these components carefully with a soft lens cloth and proprietary lens cleaner Check the thermometer fo...

Страница 40: ...focus range of 450mm 17 7in to 620mm 24 4in with a minimum target size of 2mm 0 08in A typical application for this lens is calibration on small aperture furnaces Fig 13 2 Hard carrycase open closed...

Страница 41: ...nts Its primary function is to protect the instrument from excessive radiant heat and reduce thermal shocks however it also forms a highly effective barrier against the ingress of dust The large windo...

Страница 42: ...are Parts Part Material Code Eyepiece hood 802211 Lens cover 802083 Wrist strap 801994 Battery cover 804090 Lens protection window 802061 Rubber Tripod Pad 802311 Protective thermal cover 802598 Spare...

Страница 43: ...once you have set up the thermometer to match your measurement requirements you use the User Configuration Record to make a note of your chosen parameter settings and values so that these can be re e...

Страница 44: ...on a continuous stream of lines of data of fixed 12 character length is output every 0 5 0 1 seconds EXAMPLE Q C C I 972 0 CR LF i Identifier B C100 D C055 J C390 Q C160 ii Packet C Classic while key...

Страница 45: ...E 1 000 CR LF Q 2 C T 1 000 CR LF or if disabled Q 2 C T OFF CR LF As per Advanced Mode data stream except i Packet 2 Advanced History mode packet ii Mode E Emissivity T Window Transmission iii Data I...

Страница 46: ...ced Bluetooth Heartbeat To maintain the Bluetooth link and to establish that the logger program is running the following dummy data is sent Q 0 C x xxxxxx CR LF The receiving device should send a hand...

Страница 47: ...2 Description Lost Calibration Data The Cyclops will continue to work but with the display inverted i e white on black However the calibration of the instrument will be incorrect and readings will on...

Страница 48: ...Cyclops 160B User Guide Page 42...

Страница 49: ...m 4 UNO thermometers accessories and mountings and special instruments based on UNO Application dedicated processors based on LANDMARK Graphic ABTS S and ABTS U FTS VDT S and VDT U DTT FLT5 A This 36...

Страница 50: ...environmental conditions outside the Ambient Temperature Humidity and Vibration rating of the product environmental contamination solvent vapours deposition of airborne contamination cooling liquids...

Отзывы: