Cyclops 160B
User Guide
Page 19
(u)
(v)
Window compensation
This function allows you to manually incorporate a known compensation value
into the temperature calculation, which allows for the reflectivity of unusual
combinations of viewing windows. This function can be selected
On
(u) or
Off
(v).
If you switch the function On, a screen is displayed in which you can set the
required window compensation. Use the
and
keys to adjust the value.
The default setting is
1.000
. See example in Section 9.2.
Examples:
Clear protection window fitted :
Window compensation
Off
Type 135 close-up lens fitted :
Window compensation
Off
Type 110 close-up lens fitted :
Window compensation
On
Value set to as shown on close-up lens
instruction sheet (typically 0.90)
Any combination of the above
Window compensation On
and an external viewing window
value to be determined practically
into the customer process :
(w)
About
This function (w) accesses general information about the
product. The details displayed include: calibration information,
thermometer serial number,
Bluetooth
identifier, software
version, Tmax and Tmin ambient temperature readings since last
calibration and a link to the Land Instruments website.
Note that it is necessary to use the arrow keys to scroll up and down the
screen to see the full list of information available.
(x)
(y)
Bluetooth
Bluetooth
communications allow wireless streaming of information from the
thermometer to a remote facility. The
Bluetooth
communication function
can be set to
On
(x) or
Off
(y). The default is
Off
.
Note that with
Bluetooth
switched
On
, the life of the battery will be reduced.
It is recommended that this function is switched
Off
when not required.
The complete set of menu options is shown in the flowchart (Fig. 7-6).