Page 7
•
How to connect the sensor wire
Depending on local conditions, where necessary, fit the green and red mea-
surement lines with alligator clips and for
-
NiCr measurements
match the colours to the pipe’s measuring wires.
-
Cu measurements
connect the red measurement line to the bare copper
wire and the green measurement line to the tinned copper wire.
-
HDW systems
connect the red measurement line to the red and the green
measurement line to the white measuring wire.
WARNING - Strong magnet!
Keep the pipe connection magnet away from all devices and
objects, which may be damaged by strong magnetic fields,
such as cardiac pacemakers etc., hearing aids, televisions
and monitors, bank and credit cards, data carriers and computers.
•
How to connect the pipe connection monitor
Using the banana plugs plug the two black measurement lines into the sockets
of the supplied pipe connection magnet (
13
) and position the latter parallel to
the service pipe to establish a secure point of contact.
Where there is no pipe connection magnet (
13
), the two black measurement
lines must be connected to the medium pipe without touching each other. This
is the only way to ensure that the pipe is included in the measurement.
In the event that the black measurement
lines are connected incorrectly, a “No Pipe
Contact” error message will appear on the
display and the measurement will be dis-
continued (see page 14).