Page 3
Measurement range insulation 0 .. 100 M
Ω
(fault ±1 % of m. v. for 0 .. 20 M
Ω
,
±3.0 % of m. v. for > 20 M
Ω
±1 Digit)
Resolution insulation 0.1 k
Ω
Measurement range loop 0 .. 50 k
Ω
(fault ±1 % of m. v. ±10
Ω
absolute ±1 Digit)
Resolution loop 0.1
Ω (Cu)
Pipe length NiCr: max. 2500 m (1m = 5.8
Ω
)
HDW/Cu (nordic system): max. 4000 m
Pipe contact surveillance yes
Measuring voltage
ⱕ
24 V DC, < 100 mA (acc. to EN 14419)
Display LC display, monochrome grey, glare-free
Power supply Li-Ion rechargeable battery,
operating duration 10 h typ.
Features Location tracking by GPS module
SD memory card (max. 2 GB, FAT 16)
Integrated LED torch, USB port
USB interface
Battery status display
Operating temperature -10 .. 50 °C
Admissible humidity 0 .. 95 % rel. humidity, non condensing
Dimensions (l / w / h) approx. 221 / 106 / 35 mm
Weight,
including case and accessories
approx. 1.55 kg
Technical Data
Hand-held measuring device
PipeCheck
plus
Included are a measuring cable with banana plugs and alligator clips,
pipe connection magnet, mains charger, USB cable, Li-Ion rechargeable
battery accessory kit (see below), outdoor case
and carrying bag with accessory compartment
Order-No. 075410.020
Spare parts
Measuring cable
1 m
Order-No. 075224.200
Carrying bag
with exchangeable transparency film
Order-No. 073847.100
Transparency film
for carrying bag
Order-No. 076076.000
Power supply AC/DC
100 .. 240 V AC / 12 V DC
Order-No. 073845.000
USB connection cable
PipeCheck
plus
/PC
Order-No. 073957.000
Accessories
Accessory kit
consisting of:
1 car charging cable, 2 probes, 2 large alligator clips,
1 test plug (1.1 M
Ω
/ 5.8 k
Ω, error rating of 0.1% of the respective
measurement value), 2 spring clips, 1 spare magnet,
1 pipe connection holder, 1 pipe connection extension cable,
1 spare SD memory card
Order-No. 075261.200
Ordering Data
It is imperative to read and observe all safety instructions prior to
initial operation!