10

7. 

Using the keypad, enter a specific volume to be dispensed 

based on the size of the graduated cylinder being used to 

calibrate the plain water module. 

A

B

C

D

Increase

Decrease

A. Flow Control

B. Valve Retainer 

C. Solenoid

D. Valve Body

10.  Repeat steps 8 and 9 until the designated volume is 

achieved.

11. 

Repeat steps 5 - 10 for the carbonated water module.

12. 

To re-attach the screen housing, first align the screen 

housing with the connection tabs on the unit, then rotate the 

housing down untill the connection tabs engage.

The larger the volume dispensed, the more accurate 

the results.

NOTE

Make sure both of the connection tabs are disengaged 

in the open position before attempting to re-connect 

the screen housing. Use a screw driver to open the 

connection tabs if necessary.

NOTE

8.  With a graduated cylinder placed in a position below the 

nozzle, press the 

Start Purge

 button. The unit will dispense 

the volume designated in the previous step. 

9.  Examine the dispensed volume in the graduated cylinder. If 

the dispensed volume does not match the value entered on 

the screen in step 7, use a screwdriver to adjust the  

plain water flow control. (See Plumbing Diagram on 

page 17 

for reference). 

1.  From the Service menu, press the 

Maintenance

 button.

2.  Remove the two thumb screws connecting the plastic screen 

housing to the unit (See page 9).

3.  While holding the plastic screen housing, tilt the housing 

forward until the housing disengages from the unit (See 

page 9). 

4.  While holding the screen housing, press the 

Calibrate

 tab on 

the far left side of the screen and press the 

Calibrate

 button 

for the first brand syrup module.

The water flow rate should be set from the calibration 

of the carbonated/plain water modules in the previous 

section and the ratio should be determined from when 

the brand was configured. (See page 8, Adding New 

Brand/Flavor Module)

NOTE

Calibrating Brand Syrup Modules

5. 

Using the keypad, enter a water flow rate value of 1.25 oz/

sec. 

6.  Set the Timer to the ON position and select ounces (oz) as 

the desired unit of measurement.

4.  While holding the screen housing, press the 

Calibrate

 tab on 

the far left side of the screen and press the 

Calibrate

 button 

for the plain water module. 

13. 

Re-connect the two thumb screws removed in Step 2.

14. 

Repeat steps 1 -13 for the second screen.

A

A

A. Clip in Open Position

 

Ensure there is ice on the cold plate and the lines are 

cold before attempting to set the flow rates on the 

valves. The drink temperature should be no higher  

than 40°F (4.4°C) when flow rates are set. 

NOTE

Содержание Twin Pour

Страница 1: ...ss or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if available pertaining to this unit Conta...

Страница 2: ...ing 585 lbs 265 kg Operating w Ice 745 lbs 338 kg Ice Capacity 312 lbs 142 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FITTINGS Carbonator Inlet 3 8 inch b...

Страница 3: ...re that the dispenser is level front to back and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure for the re...

Страница 4: ...n a counterclockwise direction up to a 45 angle 4 Carefully pull ADA panel and electric wire harness from the unit s splash plate until the harness connector is visible 5 Disconnect ADA harness and re...

Страница 5: ...Tube to become clogged with coffee or tea grounds or other solid particles ATTENTION 16 Reattach Drip Tray and Cup Rest to unit if applicable When installing the drip tray make sure both of the cold p...

Страница 6: ...nut on the regulator adjustment screw of the high pressure CO2 regulator connected to the source then using a screwdriver back out lock nut screw all the way DO NOT TURN ON CO2 SUPPLY AT THIS TIME WA...

Страница 7: ...d right screen by pressing the screen on off toggle buttons on the left side of the unit electrical box The manager s access to the service menu allows access to the Lighting screen see page 12 the So...

Страница 8: ...flipping the switch on the control box NOTE To check for CO2 leaks close the valve on the CO2 cylinder and observe if the pressure to the system drops with the cylinder valve closed for five minutes O...

Страница 9: ...Repeat Steps 4 and 5 for any of the other brand or flavor modules 8 Press the Menu button to return to the Service menu 12 Press the Menu button to return to the Service Menu 13 Repeat steps 1 12 for...

Страница 10: ...m on page 17 for reference 1 From the Service menu press the Maintenance button 2 Remove the two thumb screws connecting the plastic screen housing to the unit See page 9 3 While holding the plastic s...

Страница 11: ...9 for the remaining brand syrup modules 11 To re attach the screen housing first align the screen housing with the connection tabs on the unit then rotate the housing down untill the connection tabs...

Страница 12: ...sing down untill the connection tabs engage 13 Re connect the two thumb screws removed in Step 2 14 Repeat steps 1 13 for the second screen Make sure both of the connection tabs are disengaged in the...

Страница 13: ...problem with the specified brand and will dispense when activated Auto signifies that the configured Sold Out Sensor controls whether the brand can be dispensed This feature requires an optional sold...

Страница 14: ...ble water at a temperature of 90 F to 110 F Extended lengths of product lines may require additional cleaning solution Sanitizing Solution Prepare the sanitizing solution in accordance with the manufa...

Страница 15: ...twenty 20 seconds ensuring all surfaces of the nozzle have been thoroughly rinsed 9 Allow outer nozzle to air dry to expedite drying forced convection is recommended 10 Reinstall the outer nozzle to t...

Страница 16: ...ll interior surfaces of the ice chute and the ice chute feed through 29 Wearing sanitary gloves reassemble all removable parts Ensure agitator clip is locked 30 Fill unit with ice and replace Top Cove...

Страница 17: ...ement Residual sanitizing solution left in the system creates a health hazard CAUTION 7 Flush out cleaning solution from the flavor injector lines using clean warm water 8 Prepare Sanitizing Solution...

Страница 18: ...ED 3 5a C B 3 5a C B 7A C B CONTROL PCB R CONTROL PCB L ICE SOLE ICE SOLE TRIGGER TRIGGER 12VDC 12VDC 24VDC 24VDC 24VDC 115VAC 24VDC 24VDC HDMI HDMI USB USB USB USB CTRL PCB CTRL PCB LEFT SIDE VALVES...

Страница 19: ...Blk Red WHT N N N L N G V V V V GRN WHT BLK WHT BLK GRN GRN BLK WHT RED BLK RED WHT BLK WHT BLK BLK WHT WHT BLK BLK RED RED BLK GRN WHT BLK POWER SUPPLY AND IBD CONTROLLER BOX 2 to 1 adapter RIGHT RI...

Страница 20: ...6 7 6 2 2 3 8 3 4 7 4 5 SW1 SWITCH 1 NOT USED FOR MODEL 4900 ON 5 4 SWITCH AGITATOR ON TIME 5 6 OFF OFF 11 SECONDS OFF ON 9 SECONDS ON OFF 7 SECONDS ON ON 5 SECONDS SWITCH AUGER RUN TIME 7 8 OFF OFF 6...

Отзывы: