background image

Sensation

“Lancer” is the registered trademark of Lancer © 2016 by Lancer, all rights reserved.

Lancer Corporation
6655 Lancer Blvd.
San Antonio, Texas 78219
800-729-1500

Technical Support/Warranty

800-729-1550

[email protected]

lancercorp.com

PN: 28-0877/03

Operation Manual

4800

Содержание Sensation

Страница 1: ...emark of Lancer 2016 by Lancer all rights reserved Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp c...

Страница 2: ...ONS AND PART LISTINGS 22 25 Main Unit Assembly 22 23 Wiring Diagram 115 Volt 24 Plumbing Diagram 25 Counter Cutout 25 READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT This manual contains important...

Страница 3: ...d as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should service internal components of electrical control housing WARNING Make sure tha...

Страница 4: ...OXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Carbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3 8 inch barb Units are equipp...

Страница 5: ...ve enough space to install the dispenser Is countertop level Can the countertop support the weight of the dispenser Include the weight of an ice machine plus weight of ice if necessary Is dispenser lo...

Страница 6: ...each under the shroud to ensure the drain spider is secure in the coldplate cutout If the spider is not in place proceed with the following steps NOTE Inspect unit for concealed damage If evident noti...

Страница 7: ...MINIMUM of 6 152 mm AIR IN AIR IN e c n a r a e l c m m 2 5 1 6 e c n a r a e l c m m 2 5 1 6 22 559 mm M U M I N I M of 6 152 mm 34 864 mm 30 1 2 775 mm clearance above ice maker MINIMUM of 6 152 mm...

Страница 8: ...hich can cause damage to your dispenser ATTENTION 1 Install the icemaker per manufacturer specifications Points of consideration include drainage ventilation and drop zones 2 An adapter plate is requi...

Страница 9: ...ouring hot water into drain may cause the Drain Tube to collapse Allow only luke warm or cold water to enter Drain Tube Pouring coffee tea and similar substances into drain may cause the Drain Tube to...

Страница 10: ...ng at syrup pumps A B C A Syrup Pump Outlet B Syrup Pump C Fitting 4 Connect tubing from dispenser syrup inlet to the syrup pump outlet fitting Repeat for each syrup line pump Re peat Steps 1 5 for al...

Страница 11: ...to source and connect tubing 4 Using a wrench loosen lock nut on the regulator adjustment screw of the high pressure CO2 regulator connected to the source then using a screwdriver back out lock nut s...

Страница 12: ...begins to turn 7 Activate each valve to ensure a good flow of water is achieved 8 Ensure pump deck is turned OFF before turning on CO2 The pump deck has a 3 minute timeout feature If the timeout occu...

Страница 13: ...ing down 5 Install Lancer yellow syrup seperator PN 54 0031 in place of nozzle 6 Re open syrup shut off at mounting block 7 Activate valve to purge syrup until steady flow is achieved 8 Using a Lancer...

Страница 14: ...e detergent e g Sodium Laureth Sulfate dish soap with clean potable water at a temperature of 90 F to 110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a min...

Страница 15: ...surfaces of the dispenser 13 Wearing sanitary gloves reassemble all removable parts Ensure agitator clip is locked 14 Fill Unit with ice and replace Top Cover 15 Reconnect Dispenser to power source 1...

Страница 16: ...NOT rinse with water after sanitizing 7 Reconnect diffuser and nozzle 8 Connect power 9 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again 5 Remove th...

Страница 17: ...efective 1 Plug in wiring harness 2 Replace PC board 3 Replace motor Push chute motor runs but ice door does not open 1 Solenoid not connected to PC board 2 Solenoid defective 3 PC board defective 1 C...

Страница 18: ...e Erratic ratio 1 Incoming water and or syrup supply not at min flowing pressure 2 Foreign debris in water and or syrup flow control 3 CO2 regulator malfunction 1 Check pressure and adjust 2 Remove fl...

Страница 19: ...gas dispensed with syrup 1 Improper water flow to dispenser 2 Carbonator pump motor has timed out display message on the LCD screen 3 Liquid level probe not connected prop erly to PCB 4 Defective PCB...

Страница 20: ...to 70 80 PSI 0 482 0 552 MPA 2 Replace syrup supply 3 Fasten connector tightly 4 Straighten or replace lines BIB pump operating but no flow 1 Leak in syrup inlet or outlet line 2 Defective BIB pump 1...

Страница 21: ...light is off check to see if the internal circuit breaker on the transformer has tripped If it has tripped it can be reset by depressing the switch on the top of the transformer D7 This light flashes...

Страница 22: ...et the agitation time should be less than the dispense time If using an icemaker the agitation time can be decreased 7 seconds 5 seconds 7 seconds 9 seconds 11 seconds To prevent possible harm to the...

Страница 23: ...23 INTENTIONALLY LEFT BLANK...

Страница 24: ...24 Main Unit Assembly ILLUSTRATIONS AND PART LISTINGS 2 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22...

Страница 25: ...Shaft Motor 9 03 0368 Retainer Pin Agitator IBD 10 10 0762 Pin Agitator IBD Single Retainer 11 05 1476 01 Lid Front IBD 12 05 2370 Lid Back 30 Mercury 13 82 4363 Agitator Assy Angled P Ice 14 82 4315...

Страница 26: ...26 Wiring Diagram 115 Volt...

Страница 27: ...1 2 3 SODA WATER 6 7 8 SODA WATER 4 SODA WATER 5 SYRUP 2 SYRUP 3 SYRUP 4 SYRUP 5 SYRUP 6 8 7 6 3 2 1 RECOMMENDED PLUMBING SYRUP LINES NOT SHOWN 3 1 1 3 CONFIGURATION FOR ASSISTANCE CALL 1 800 729 150...

Страница 28: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: