18
TROUBLE
CAUSE
REMEDY
Insufficient soda flow
(carbonated drinks)
1.
Insufficient CO
2
supply pressure
2.
Shutoff on mounting block is not fully open
3.
Foreign debris in soda flow control
4.
Defective LFCV module
1.
Verify incoming CO2 pressure is between
70-75 PSI (0.482 - 0.517 MPA)
2.
Open shutoff fully
3.
Remove soda flow control from valve and
clean out any foreign material to ensure
smooth spool movement
4.
Replace module
Insufficient water flow (plain
water drinks)
1.
Insufficient incoming supply pressure
2.
Shutoff on mounting block not fully open
3.
Foreign debris in water flow control
4.
Water filtration problem
5. Defective LFCV module
1.
Verify incoming supply water pressure to
plain water inlet is a min of 75 PSI (0.517
MPA), max of 125 PSI (0.862 MPA).
2.
Open shutoff fully
3.
Remove water flow control from valve and
clean out any foreign material to ensure
smooth spool movement
4.
Service water system as required
5. Replace module
Erratic ratio
1.
Incoming water and/or syrup supply not at
min flowing pressure
2.
Foreign debris in water and/or syrup flow
control
3. CO
2
regulator malfunction
1.
Check pressure and adjust
2.
Remove flow control from suspected valve
and clean out any foreign material to
ensure smooth spool movement
3.
Repair or replace CO
2
regulator
Insufficient syrup flow
1.
Insufficient CO
2
pressure to BIB pumps
2.
Shutoff on mounting block not fully open
3.
Foreign debris in syrup flow control
4.
Defective BIB pump
1.
Adjust CO
2
pressure to BIB pumps to
80 PSI (0.552 MPA) (min. 70 PSI (0.482
MPA)). Do not exceed manufacturer’s
recommendations
2.
Open shutoff fully
3.
Remove syrup flow control from valve and
clean out any foreign material to ensure
smooth spool movement
4.
Replace pump
Valve will not shut off
1. Debris in solenoid seat
2. Solenoid plunger sticking
1.
Activate valve a few times to free debris.
Remove the solenoid coil and plunger.
Clean out any foreign material
2.
Replace solenoid coil
Water continually leaking at
connections
1.
Loose water connections
2.
Flare seal washer leaks
1.
Tighten water connections
2.
Replace flare seal washer