background image

!

WARNING

 TO AVOID DAMAGING THE UNIT, DO NOT OVERTIGHTEN WATER FLOW CONTROL CONNECTOR.

ADVERTENCIA

 PARA EVITAR DAÑAR LA UNIDAD, NO EN EXCESO DE CONTROL DE FLUJO DE AGUA  

CONECTOR.

AVERTISSEMENT

 POUR ÉVITER D’ENDOMMAGER L’UNITÉ, NE PAS TROP SERRER LE CONTRÔLE DU DÉBIT 

D’EAU CONNECTEUR.

 

6.11  WATER CALIBRATION VALVE REMOVAL

 

 

A.   Remove fan/coil assembly.

 

 

B.   Disconnect waterproof connectors on solenoid and flowmeter.

 

 

C.   Slide the two retainers on the top and bottom of the water calibration valve assembly to the   

 

“disengage” position.

 

 

D.   Push the water calibration valve assembly down until the outlet connector tube telescopes into  

 

the base of the unit.

 

 

E.   While holding the outlet connector tube, lift up on the water calibrations valve assembly to 

 

 

 

disengage it from the outlet connector tube.

 

 

F.   Remove the water calibrations valve assembly, being careful not to lose the flow washer that is  

 

fitted in the top end of the outlet connector tube.

 

 

G.   Replacement is as follows:

 

 

 

1.   Position the outlet end of the water calibrations valve assembly on the outlet connector   

 

 

tube and fasten securely by sliding the retainer on the water calibrations valve assembly to  

 

 

the locked position.

 

 

 

2.   Lift up on the water calibrations valve assembly to withdraw the outlet connector tube from  

 

 

the base of the unit and fit the assembly to the manifold outlet.

 

 

 

3.   Secure the water calibrations valve assembly to the manifold outlet by sliding the retainer to  

 

 

the locked position.

 

 

 

4.   Reconnect the waterproof connectors.

 

 

 

5.   Replace the back plate/fan assembly making sure that 1) the wire leads are not pinched  

 

 

between the back plate and the base of the unit and 2) that the bottom edge of the back  

 

 

plate fits between the pairs of standing ribs of the base. Secure the back plate with the two  

  screws.

 

6.12  FLOW WASHER REPLACEMENT

 

 

A.   Remove mixing nozzle.

 

 

B.   Remove the flow control connector.

 

 

C.   Remove flow washer from the water fitting.

!

WARNING

 DISCONNECT POWER BEFORE ATTEMPTING TO REMOVE THE POWER BOX.

ADVERTENCIA

 DESCONECTE LA ENERGÍA ANTES DE INTENTAR QUITAR LA CAJA DE ALIMENTACIÓN.

AVERTISSEMENT

 COUPEZ L’ALIMENTATION ÉLECTRIQUE AVANT DE RETIRER LE BLOC D’ALIMENTATION.

21

 

 

D.   Replacement is the reverse of removal. For proper installation, ensure the concave side of the  

 

flow washer is not visible.

 

6.13  POWER SUPPLY BOX REMOVAL

 

 

A.   Remove the drip tray by gently lifting the drip tray up and away from the unit.

 

 

B.   Remove the splash plate by pulling the bottom up slightly, then out from the unit.

 

 

C.   Remove the drain tube from the bracket (mounted on the side of the power supply box) by 

 

 

 

pulling up until it clears the bracket.

 

 

D.   Disconnect the main power feed lead and the harness to the compressor deck from the 

    transformer 

box.

 

 

E.   Disconnect the power feed harness at the electronics box screws that exit from the power 

    supply 

box.

 

 

F.   Remove the two screws that secure the power supply box to the power supply bracket and   

 

remove the power box.

 

 

G.   Replacement is the reverse of removal.

Содержание MOO

Страница 1: ...l Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0716 01 10 07 10 FOR QUALIFIED INSTALLER ONLY MOO Milk Dispenser 115V 60Hz Operation Manual PN 28 0716 01 Lancer is...

Страница 2: ...CAUTIONS 6 9 1 INSTALLATION 10 1 1 UNPACKING 10 1 2 SELECTING A COUNTER LOCATION 10 1 3 INSTALLING THE DISPENSER 10 11 1 4 KEYLOCK SWITCH 11 1 5 PURGING AIR FROM THE WATER SYSTEM 11 2 OPERATING THE U...

Страница 3: ...CTRONICS BOARD REMOVAL 22 6 15 WRAPPER REMOVAL 22 7 TROUBLESHOOTING 22 26 8 DISPENSER DISPOSAL 26 9 ILLUSTRATIONS PARTS LISTINGS WIRING AND WATER FLOW DIAGRAMS 26 9 1 COMPRESSOR DECK ASSEMBLY 28 29 9...

Страница 4: ...PSI 0 241 MPA Max operating pressure 90 PSI 0 621 MPA FITTINGS Plain water inlet 3 8 barb hose fitting Water pipe connections and fixtures directly connected to a potable water supply must all be size...

Страница 5: ...stall the dispenser Include space for a top mounted ice machine if necessary Does the top mounted ice machine have a minimum clearance on all sides Located away from direct sunlight or overhead lighti...

Страница 6: ...los ni os sin supervisi n Esta unidad no ha sido dise ada para suministrar productos l cteos La temperatura ambiente operativa m nima m xima para el dispensador es de 40 F a 90 F 4 C a 32 C No opere l...

Страница 7: ...e corriente o sistema de proteccion similar 4 Hay una demora de 5 minutos que evita que el compresor y el abanico del condensador arranquen hasta pasado ese tiempo Si hay algun corte en la corriente e...

Страница 8: ...enance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should service internal componen...

Страница 9: ...mperantes El suministro de agua debe estar protegido por una separaci n de aire un dispositivo de prevenci n del contraflujo situado antes del sistema de inyecci n de CO2 u otro m todo aprobado para c...

Страница 10: ...ox open Remove power cord and set aside E Run hose through front of unit to access panel in back Pull through See Figure 1 F Cut other end of hose to length Slide oetiker clamp onto hose Insert approp...

Страница 11: ...system remains on but the unit will not dispense product 2 ON In this position the refrigeration system remains on and the unit dispenses product 3 FLUSH In this position the refrigeration system rem...

Страница 12: ...OUT FEATURE Once the package is changed turn the key to the FLUSH position and touch the in the bottom left hand corner of each touch pad affected until CHANGE PACKAGE appears Turn the keyswitch to ON...

Страница 13: ...will display 3 is the left pump 1 is the right pump Toggle using the and button To select press the PUSH button 2 To Reset Pump Revolutions 3 View Version Shows the software version 4 Press PUSH to r...

Страница 14: ...e prepared Other Supplies Needed Sanitary gloves Clean cloth towels Extra nozzle Bucket WARNING IF A POWDER SANITIZER IS USED DISSOLVE IT THOROUGHLY WITH HOT WATER PRIOR TO ADDING TO THE SYRUP SYSTEM...

Страница 15: ...emove drip tray and cuprest Wash in warm water using a mild detergent Rinse with warm water and reinstall I Ensure draintube into drip tray is properly seated Close door WARNING DO NOT SOAK NOZZLES IN...

Страница 16: ...ater 4 3 REFRIGERATION SYSTEM The unit has a lift out refrigeration deck The compressor condenser fan and agitation motors evaporator and ice bank control system are mounted on a common deck plate The...

Страница 17: ...E MISE LA TERRE LA DISTRIBUTRICE DOIT TRE MISE LA TERRE LECTRIQUEMENT CORRECTEMENT POUR VITER DES BLESSURES GRAVES OU UNE D CHARGE LECTRIQUE MORTELLE LE CORDON D ALIMENTATION A UNE FICHE TROIS BRANCHE...

Страница 18: ...the water from the system C Remove the splash plate Slide the locking clip on the Shut Off Valve to release the inlet fitting and remove the inlet fitting from the valve leaving the valve connected t...

Страница 19: ...e gas spring and slide the pin out of the clevis that anchors the gas spring to the door Rotate the gas spring down and out of your way C Remove pin that secures the gas spring to the top clevis same...

Страница 20: ...location resting it on the bottom surface of the ice NOTE For this step request assistance if necessary Lift the deck relatively straight to prevent the ice bank from wedging against the sides of the...

Страница 21: ...ly to the manifold outlet by sliding the retainer to the locked position 4 Reconnect the waterproof connectors 5 Replace the back plate fan assembly making sure that 1 the wire leads are not pinched b...

Страница 22: ...ITION OFF CELA TRANSFORME LA PUISSANCE PRINCIPALE DU CIRCUIT PLANCHES HORS ET EMP CHE D ARC AU NIVEAU DU CONNECTEUR ET EMP CHE BORD DOMMAGE POUR LES CONSEILS E Turn the five plastic standoffs one half...

Страница 23: ...fective ice bank control PCB H Defective compressor A Connect unit power cord to electrical outlet B Reset circuit breaker or replace fuse If problem persists 1 check unit for electrical short 2 elect...

Страница 24: ...eck C Replace condenser fan motor D Clean condenser E Check for obstructions at air intake exhaust F Replace agitator motor DISPENSING SYSTEM TROUBLESHOOTING The Dispensing System is controlled by the...

Страница 25: ...Remove fan plate and check connections at water calibration valve Rectify if necessary 3 Swap suspect water calibration valve with a known working assembly and retest If valve now functions replace wa...

Страница 26: ...ith other pump head If pump head works properly after swapping the problem lies with the pump drive Proceed to next step If pump head does not work properly after swapping the problem lies with the pu...

Страница 27: ...NOTES 27...

Страница 28: ...RESSOR DECK ASSEMBLY ICE BANK CONTROL BOX WIRING AGITATOR WHITE POWER FAN TO COMP BLK 7 53 16 42 20 22 21 26 25 24 23 43 2 35 40 36 11 19 4 19 45 31 30 29 33 12 15 13 5 19 37 14 10 18 17 50 18 19 51 4...

Страница 29: ...05 Relay 24 12 0004 Overload 25 13 0006 Cover Terminal 26 03 0040 Bail Strap 27 52 1633 Probe Ice Bank Control 28 04 0633 Screw 8 19 x 0 437 SS 29 47 1408 Tube Suction 30 51 0061 Accumulator 31 50 021...

Страница 30: ...9 2 WATER CIRCUIT TANK ASSEMBLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 30...

Страница 31: ...Tank Front 6 01 0797 Nut Compress Align 3 8 Tube 7 50 0264 Insulation Tank Left 8 50 0266 Insulaton Tank Back 9 50 0263 Insulaton Tank Right 10 05 0955 Support Coil Water 11 04 0723 Stud Locator 12 1...

Страница 32: ...9 3 INSULATED TANK ASSEMBLY 1 2 3 4 5 6 7 8 8 8 9 1 10 11 12 13 14 14 15 16 17 18 19 20 14 21 22 23 24 25 26 27 32...

Страница 33: ...et 12 48 1053 Tube Assy Fitting Elbow Water in 13 52 3132 Power Supply Box Assembly 14 04 0504 Screw 8 18 x 375 PHD W ELW 15 51 6133 Weldment Bracket Power Supply 16 04 0297 Nut Hex 8 32 Keps SS 17 51...

Страница 34: ...9 4 INTERNAL CABINET ASSEMBLY 1 2 3 4 5 6 7 8 9 6 10 11 12 10 13 14 34...

Страница 35: ...crew 8 32 x 500 PHD PH MS 6 04 0470 Screw 6 19 x 500 PHD PH SL 7 05 2554 Retainer Seal 8 04 1531 Dowel 3 8 OD x 1 4 LG 9 48 2599 Tube Assy Interface Valve 10 02 0089 O Ring 11 52 3103 Harness Assy Pro...

Страница 36: ...9 5 PUMP PLATFORM ASSEMBLY 1 2 3 4 5 6 8 9 10 7 36...

Страница 37: ...x 438 BH PH 3 04 0406 Screw 6 32 x 375 PH PH MS 4 51 6228 Weldment Chimney Plate 5 54 0429 Base Assy MTG Wave Pump 6 82 3896 Platform Sub Assembly Wave Pump 7 86 0167 Pump Motor Housing Drive Assembly...

Страница 38: ...9 6 WRAPPER DOOR DRIP TRAY ASSEMBLY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 38...

Страница 39: ...y Switch 7 04 0750 Screw 6 32 x 812 PHD PH Rolok 8 82 1726 Top Cover Assy 9 30 6279 Bracket 10 04 0504 Screw 8 18 x 375 PHD 11 04 0788 Screw 6 32 x 438 BHD PH 12 05 2190 Plug Fascia 13 81 0307 Pin Doo...

Страница 40: ...WATER MODULE 1 COOLING FAN 1 2 WAVE PUMP 2 WATER MODULE 2 COOLING FAN 3 4 CPU POS 2 POS 1 REAR INDICATORS 32VDC INPUT RIGHT DOOR LEFT DOOR KEY SWITCH TEMP FOR FUTURE USE TEMP SENSOR RIGHT DOOR LEFT DO...

Страница 41: ......

Страница 42: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...