background image

4

Unpack the Dispenser

1. 

Set shipping carton upright on the floor then cut package 

banding straps and remove.

2.  Open top of carton and remove interior packaging. 
3. 

Lift carton up and off of the unit.

4.  Remove plywood shipping base from unit by moving unit so 

that one side is off the counter top or table allowing access   

to screws on the bottom of the plywood shipping base.

Selecting/Preparing Counter Location

5.  Remove accessory kit and loose parts from ice compartment.

6.  If leg kit has been provided, assemble legs by tilting unit.

4.  Unit may be installed directly on countertop or on legs. If 

installed directly on the counter, unit must be sealed to the 

countertop with an FDA approved sealant. If an icemaker is 

to be mounted on top of dispenser, do not install dispenser 

on legs. 

5.  Select a location for the remote pump deck, syrup pumps, 

remote flavor shot syrup pumps (if necessary), CO

2

 tank, 

syrup containers, and water filter (recommended).                                                                                  

6.  Using  Counter  Cutout  Template  provided,  cut  out  required                                                                                      

opening for the water, syrup, and CO

2

 lines in the designated 

dispenser location.

AIR O

UT

AIR

 OUT

AIR

  IN

AIR

 OUT

AIR

  IN

AIR OU

T

Minimum 6” (152 mm)

clearance above ice maker

 

6” (152 mm) clearanc

e

6” (152 mm) clearanc

e

6” (152 mm) clearanc

e

 

DO NOT LAY UNIT ON ITS SIDE OR BACK

ATTENTION

 

If unit is to be transported, it is advisable to leave the 

unit secured to the plywood shipping base.

 

NOTE

 

Inspect unit for concealed damage. If evident, notify 

 

delivering carrier and file a claim against the same.

NOTE

1.  Select a level, well ventilated location that is in close       

proximity to a properly grounded electrical outlet, within five 

(5) feet (1.5 m) of a drain, a water supply that meets the 

requirements shown in the Specifications section found on 

pages 4-6, away from direct sunlight or overhead lighting, 

and has sufficient clearance for air circulation. 

2. 

Sufficient clearance must be provided, if an ice maker is not 

installed, to allow filling ice compartment from a five gallon 

bucket (a minimum of 16 inches is recommended). 

3.  The selected location should be able to support the weight of 

the dispenser, ice and possibly an icemaker being installed 

after counter cut out is made. Total weight (with icemaker) for 

this unit could exceed 800 pounds (363.6kg).

 

The dispenser should only be installed in a location 

where it can be overseen by trained personnel

NOTE

 

Lancer does 

NOT

 recommend the use of shaved or

 

flake ice in the dispenser.

NOTE

In order to facilitate proper dispenser drainage, ensure 

that the dispenser is level, front to back and side to 

side. Place a level on the top of the rear edge of the  

dispenser. The bubble must settle between the level 

lines. Repeat this procedure for the remaining three 

sides. Level unit if necessary. For optimum perfor-

mance place the unit at a 0° tilt. The maximum tilt is 5°.

Leveling the Dispenser:

Installing an Icemaker (if necessary)

When installing an icemaker on the dispenser, use a 

bin thermostat to control the ice level (see below). This 

will prevent damage to the dispensing mechanism. The 

bracket for mounting a thermostat is located in the ice 

bin. During the automatic agitation cycle and while    

dispensing ice, ensure there is adequate space be-

tween the top of the ice level and the bottom of the 

icemaker so the ice can move without obstruction. 

Contact your icemaker manufacturer for information  

on a suitable bin thermostat.

ATTENTION

1. 

Install the icemaker per manufacturer specifications. Points 

of consideration include drainage, ventilation, and drop 

zones.

2.  An adapter plate is required when installing an icemaker. 

Contact your Sales Representative or Lancer Customer 

Service for more information.

3.  A bin thermostat is required in order to control the level of ice 

in the dispenser (Refer to ATTENTION above). Contact your 

icemaker manufacturer to obtain the correct bin thermostat. 

4.  Bin thermostat should be a minimum of 2” below the top 

edge of the dispenser. The preferred location of the bin   

thermostat is on the left side wall. 

Failure to use an ice bin thermostat will not only void 

your IBD’s warranty but will result in the inability to 

control the level of ice in the ice bin which can cause 

damage to your dispenser.

ATTENTION

4”

Attach Bin Stat Bracket As Shown

Recommended Bin Stat Attachment

Bulb

Tube

Содержание Blue Star IBD CB Series 22

Страница 1: ...lancercorp com for immediate access or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if availa...

Страница 2: ...arbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3 8 inch barb CO2 Inlet 3 8 inch barb ELECTRICAL 115 VAC 60 Hz 3 6 Amps 230 VAC 50 60 Hz 1 5 Amps PLAIN WATER SUPPLY Mi...

Страница 3: ...he 25 8 valve dispensers have space restrictions so the two center valves are plumbed only for carbonated watered drinks and are non adjustable NOTE A B C E A Plain Water ON D Water Closed B Carb Wate...

Страница 4: ...ed location should be able to support the weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 p...

Страница 5: ...et of the proper voltage and amperage rating DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL OUTLET AT THIS TIME Make sure that all water lines are tight and unit is dry before making any electrical connect...

Страница 6: ...2 regulator manifold A B C D A Line to Dispenser B Line to Syrup Pumps C Line to CO2 Regulator D CO2 Regulator Manifold DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING 7 Repeat Step 6 on the previous p...

Страница 7: ...isting counter clockwise and pulling down then remove diffuser by pulling down 5 Install Lancer yellow syrup seperator PN 54 0031 in place of nozzle The pump deck has a 3 minute timeout feature If the...

Страница 8: ...es when cleaning and sanitizing syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects ste...

Страница 9: ...10 Wearing sanitary gloves soak and clean cloth towel in Sanitizing Solution and wash all surfaces of removable parts sides of the Ice Bin Auger and surface of the aluminum casting 11 Using the Saniti...

Страница 10: ...to flush solution from the dispenser 11 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again 9 Place syrup lines into sanitizing solution and activate ea...

Страница 11: ...hown Syrup Lines Not Shown 30 10 Valve To prevent possible harm to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product...

Страница 12: ...WIRING DIAGRAM Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: