• WARNING:
Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO
2
may
displace oxygen in the blood.
• WARNING:
Prolonged exposure to CO
2
can be harmful. Personnel exposed to high concentrations of CO
2
gas will experience
tremors which are followed by a loss of consciousness and suffocation.
• WARNING:
If a CO
2
gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak.
• WARNING:
Strict attention must be observed in the prevention of CO
2
gas leaks in the entire CO
2
and soft drink system.
5
Carbon Dioxide (CO
2
)
Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable water supply must
be sized, installed, and maintained according to federal, state, and local laws. The water supply line must be at least a 3/8 inches
(9.525 mm) pipe with a minimum of 25 PSI (0.172 MPA) line pressure, but not exceeding a maximum of 65 PSI (0.448 MPA).
Water pressure exceeding 65 PSI (0.448 MPA) must be reduced to 65 PSI (0.448 MPA) with an approved water pressure regulator.
Use a filter in the water line to avoid equipment damage and beverage off-taste. Check the water filter periodically, as required by
local conditions. The water supply must be protected by means of an air gap, a backflow prevention device or another approved
method to comply with NSF standards. A leaking inlet water check valve will allow carbonated water to flow back through the pump
when it is shut off and contaminate the water supply. Ensure the backflow prevention device complies with ASSE and local stan-
dards. It is the responsibility of the installer to ensure compliance.
!
Water Notice
SPECIFICATIONS & FEATURES
DIMENSIONS
Width
: 22.0 inches (599 mm)
Depth
: 30.5 inches (775 mm)
Height
: 40.25 inches (1022 mm)
WEIGHT
Shipping
: 310 lbs (141 kg)
Empty (w/out ice)
: 280 lbs (127 kg)
Ice Capacity
: 200 lbs (91 kg)
CARBON DIOXIDE (CO
2
) SUPPLY
Min Pressure
: 70 PSIG (0.483 MPA)
Max Pressure
: 80 PSIG (0.552 MPA)
FITTINGS
Carbonator Inlet
: 3/8 inch barb
Plain Water Inlet
: 3/8 inch barb
Brand Syrup Inlets
: 3/8 inch barb
CO
2
Inlet
: 3/8 inch barb
ELECTRICAL
115 VAC / 60 Hz / 3.6 Amps
230 VAC / 50-60 Hz / 1.5 Amps
PLAIN WATER SUPPLY
Min Flowing Pressure
: 75 PSIG (0.516 MPA)
CARBONATED WATER SUPPLY
Min Flowing Pressure
: 25 PSI (0.172 MPA)
Max Static Pressure
: 65 PSI (0.448 MPA)
This unit emits a sound pressure level below 70 dB
Blue Star IBD CB Series 22”
CARBON DIOXIDE (CO
2
) SUPPLY
Min Pressure
: 70 PSIG (0.483 MPA)
Max Pressure
: 80 PSIG (0.552 MPA)
FITTINGS
Carbonator Inlet
: 3/8 inch barb
Plain Water Inlet
: 3/8 inch barb
Brand Syrup Inlets
: 3/8 inch barb
Flavor Shot Inlets
: ““ inch barb
CO
2
Inlet
: 3/8 inch barb
DIMENSIONS
Width
: 25.0 inches (635 mm)
Depth
: 30.5 inches (775 mm)
Height
: 40.25 inches (1022 mm)
WEIGHT
Shipping
: 331 lbs (150 kg)
Empty (w/out ice)
: 295 lbs (134 kg)
Ice Capacity
: 234 lbs (106 kg)
ELECTRICAL
115 VAC / 60 Hz / 3.6 Amps
230 VAC / 50-60 Hz / 1.5 Amps
PLAIN WATER SUPPLY
Min Flowing Pressure
: 75 PSIG (0.516 MPA)
CARBONATED WATER SUPPLY
Min Flowing Pressure
: 25 PSI (0.172 MPA)
Max Static Pressure
: 65 PSI (0.448 MPA)
This unit emits a sound pressure level below 70 dB
Blue Star IBD CB Series 25” & Renew IBD CB Series 25”
Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.
Do not plug
into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local
electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with
this unit. Do not ‘gang’ together with other electrical devices on the same outlet. The keyswitch does not disable the line voltage to
the transformer primary. Always disconnect electrical power to the unit to prevent personal injury before attempting any internal
maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source
to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all
water lines are tight and units are dry before making any electrical connections!
F
Electrical Warning