13
PROGRAMMING AND CONFIGURATION
A
B
D
H
I
E
C
F
J
G
A. Brand 1
B. Brand 2
C. Brand 3
D. Brand 4
E. Water Button
F. SM (Small) Portion Control
G. MD (Medium) Portion Control
H. LG (Large) Portion Control
I. XL (X-Large) Portion Control
J. Mode LED
The following sections are for Multi-brand units with Volumetric or LFCVs ONLY. Does not apply for Single Brand units.
NOTE
Valve Configuration
1. On the main board in the junction box, there is a SW1
switch that determines how the valves on the tower work.
Any changes to the SW1 switch will cause the dispenser to
reset.
2. Leave Toggle 1 in the OFF position for the valves to be in
LFCV mode.
3. Switch Toggle 1 to the ON position for the valves to be in
Volumetric mode.
4.
Switch Toggle 2 to the ON position to enable product to be
dispensed by pressing and holding the brand buttons.
5. Leave Toggle 2 in the OFF position to require the use of the
handle to dispense product.
Programming Overview