19
TROUBLE
CAUSE
REMEDY
Circuit breaker tripping.
1. Valve wire harness shorted to itself or to
faucet plate.
2. PCB is bad.
3. Secondary wire harness is bad.
4.
Transformer failure.
1. Detect short by disconnecting input fasten
to keylock and single pin connector.
Restore power if breaker doesn’t trip.
Then valve wire harness is shorted. If OK,
reconnect.
2. Detect short by disconnecting J1
connector (24 VAC input) from PCB.
Restore power, if breaker doesn’t trip.
Then replace PCB. If breaker does trip,
then PCB is OK. Reconnect J1 connector.
3. If it does not trip, locate short in secondary
harness between transformer, PCB, and
valve wire harness.
4.
Detect short by disconnecting both
transformerfastons and restore power. If
breaker does trip, replace transformer.
BIB pump does not operate
when dispensing valve opened.
1. Out of CO
2
, CO
2
not turned on, or low CO
2
pressure.
2. Out of syrup.
3. BIB connector not tight.
4.
Kinks in syrup or gas lines.
5.
Bad BIB Pumps.
1. Replace CO
2
supply, turn on CO
2
supply, or adjust CO
2
pressure to 70-80
PSI (0.483-0.552 MPA)
2. Replace syrup supply.
3. Fasten connector tightly.
4.
Straighten or replace lines.
5.
Replace BIB pump.
BIB pump operated, but no
flow.
1. Leak in syrup inlet or outlet line.
2. Defective BIB pump check valve.
1. Replace line.
2. Replace BIB pump
BIB pump continues to operate
when bag is empty.
1. Leak in suction line.
2.
Leaking o-ring on pump inlet fitting.
1. Replace line.
2. Replace o-ring.
BIB pump fails to restart after
bag replacement.
1. BIB connector not on tight.
2. BIB connector is stopped up.
3. Kinks in syrup line
4.
Bad BIB Pumps.
1. Tighten BIB connector.
2. Clean out or replace BIB connector.
3. Straighten or replace line.
4.
Replace BIB pump.
BIB pump fails to restart when
dispensing valve is closed.
1.
Leak in discharge line or fittings.
2. Empty BIB.
3. Air leak on inlet line or bag connector.
1. Repair or replace discharge
2. Replace BIB.
3. Repair or replace.
Low or no carbonation.
1. Low or no CO
2
.
2. Excessive water pressure.
3. Worn or defective carbonator pump.
1. Check CO
2
supply. Adjust CO
2
pressure to
70 PSI (0.483 MPA).
2.
Water regulator should be set at 50 PSI
(0.345 MPA)
3. Replace carbonator pump.
To prevent possible harm to the environment from improper disposal, recycle the unit
by locating an authorized recycler or contact the retailer where the product was purchased.
Comply with local regulations regarding disposal of the refrigerant and insulation.
Dispenser Disposal
Содержание 85-3151R-20-11111-22
Страница 27: ...27 Wiring Diagram LFCV...
Страница 28: ...28 Wiring Diagram VV...
Страница 29: ...29 Counter Cutout Not to Scale...