3
dispenser.
E. Turn on water supply and check for leaks.
F.
Using test gauge assembly (PN 22-0138), set regulator at 50 PSIG (3.52 kg/cm
2
).
1.10 CONNECTING THE CO
2
SUPPLY
A. Connect high pressure CO
2
regulator assembly to CO
2
cylinder. Use a new CO
2
tank washer if
regulator does not have built-in o-ring seal.
B. Place CO
2
cylinder in service location under counter, etc., and secure it with a safety chain.
C. Using tubing and fittings from installation kit connect tubing assembly to tank mount regulator
using flare seal washer (PN 05-0011). Use a back-up wrench to prevent damage to regulator
assembly.
D. Route gas line through hole in counter and through opening behind the dispenser splash plate.
E. Leave 12 inches (30 cm) of extra tubing length below the counter for servicing and moving the
dispenser.
F.
If the unit is equipped with internal mini-pumps, remove the protective plug from the CO
2
manifold (located on front of mini pumps on right side of unit) and connect the CO
2
supply line
using a 1/4 inch elbow (supplied in installation kit.)
CAUTION
DO NOT TURN ON THE CO
2
SUPPLY AT THIS TIME
G. If dispenser does not have built in syrup pumps, connect directly to the carbonator CO
2
inlet
check valve.
1.11 CONNECTING TO BAG-IN-BOX (BIB) SYRUP SUPPLY (Units with built-in Syrup Pumps)
CAUTION
THE SYRUP INLET TUBE ASSEMBLIES SHIPPED WITH THE INSTALLATION KIT ARE EIGHT (8)
FEET (2.4 M) LONG. THESE LINES CAN BE EXTENDED UP TO A MAXIMUM OF 12 FEET
(3.7 M). THE MAXIMUM HEIGHT OF THE PUMPS ABOVE THE LOWEST BIB PACKAGE
SHOULD NOT EXCEED EIGHT (8) FEET (2.4 M). IF EITHER THE HEIGHT OF PUMPS OR
LENGTH OF INLET LINE LIMITATIONS IS EXCEEDED, REMOTE SYRUP PUMPS OR
PRESSURIZED SYRUP CONTAINERS SHOULD BE USED.
A. Remove the protective caps from the syrup pump inlets and connect syrup inlet tube assemblies
furnished in the installation kit to the syrup pumps. Lubricate o-rings before installation using
water or an approved FDA lubricant. Be careful not to cut o-rings when installing in pump.
B. Mark syrup tube assemblies at BIB hose connector end with product ID tape.
C. Route the syrup supply tubes from the unit through hole in counter to the BIB syrup supply.
D. Dip hose connectors in a cup of warm water.
E. Attach the BIB hose connectors to the appropriate syrup flavor.
1.12 CONNECTING TO REMOTE BIB SYRUP PUMPS
A. Install the remote BIB, syrup supply and pumps in a convenient location.
B. Attach the syrup supply tubes to the dispensers syrup inlet fittings (located behind the splash
plate) using a 1/4 inch Oetiker clamp for each syrup flavor.
C. Route the syrup supply tubes to the remote syrup pumps.
D. Complete installation of the remote syrup pump system following the manufacturer’s
instructions.
1.13 CONNECTING TO REMOTE PRESSURIZED SYRUP SUPPLY
A. Place the five (5) gallon (Figal) syrup containers and the CO
2
cylinder and regulator in a
convenient location.
B. Attach the syrup supply tube assembly to the dispensers syrup inlet fittings (located behind the
splash plate) using a 1/4 inch Oetiker clamp for each syrup flavor.
C. Route the syrup supply tubes to the Figal syrup containers and attach them to the appropriate
syrup flavor.
D. Attach a CO
2
supply line from each of the Figal syrup containers to the low pressure regulator
and pressurize the containers.