1
1.
INSTALLATION
1.1
RECEIVING
Each unit is completely tested under operating conditions and thoroughly inspected before
shipment. At the time of shipment, the carrier accepts the unit and any claim for damage must be
made with the carrier. Upon receiving units from the delivering carrier, carefully inspect carton for
visible indication of damage. If damage exists, have carrier note same on bill of lading and file claim
with carrier.
1.2
UNPACKING
A. Cut plastic banding and remove.
B. Remove top portion of carton by lifting up.
C. Remove accessory kit and loose parts from top packaging.
D. Remove top inner carton pad and corners.
E. Lift unit up by plywood shipping base and remove lower portion of carton.
F.
Inspect unit for concealed damage and if evident notify delivering carrier and file a claim against
same.
G. Remove plywood shipping base from unit by moving unit so that one side is off the counter top
or table allowing access to screws on the bottom of the plywood shipping base.
NOTE
If unit is to be transported it is advisable to leave the unit secured to the plywood base.
H. If unit is to be installed with optional legs, assemble legs to unit by tilting unit.
DO NOT LAY
UNIT ON ITS SIDE OR BACK.
1.3
UNPACKING INSTALLATION KITS
A. Inspect kits for concealed damage and if evident, notify delivering carrier and file a claim against
same.
B. Each kit contains a list of the parts and a drawing showing the proper assembly of the parts.
1.4
SELECTING A COUNTER LOCATION
A. Select a location close to a properly grounded electrical outlet and water supply that meet the
requirements as scheduled on the SPECIFICATION page.
B. Counter location must be able to support a minimum of 250 pounds (113.6 kg).
CAUTION
FAILURE TO MAINTAIN SPECIFIED CLEARANCE WILL CAUSE THE COMPRESSOR TO
OVERHEAT AND WILL RESULT IN COMPRESSOR FAILURE.
C. Condenser air is drawn in the back of the unit and discharged out the top of the unit.
A
minimum of eight (8) inches (20.3 cm) clearance must be maintained over the top of the unit and
a minimum of six (6) inches (15.2 cm) clearance must be maintained behind the unit to ensure
proper air circulation. Failure to do so will result in compressor failure.
1.5
MOUNTING THE DISPENSER
A. The dispenser is designed to be permanently mounted and sealed to the counter, or installed on
four (4) inch legs.
NOTE
NSF listed units must be sealed to the counter or have four (4) inch legs installed.
B. For permanent mounting, use Lancer sealant kit (PN 15-0010) to seal the dispenser to the
counter.
C. For leg mounting, use Lancer leg kit (PN 82-0569).
1.6
CONNECTING THE DRAIN
A. Remove cup rest. Lift splash plate up and pull out and down on the bottom to remove.
B. Remove the drip tray from the unit and connect the drain tube to the drain fitting located on the
back.