background image

ITEM

PART NO. DESCRIPTION

-

82-2662

Compressor Deck Assy, 115V/60Hz

-

82-2665

Compressor Deck Assy, 230V/50Hz

-

82-2666

Compressor Deck Assy, 240V/60Hz

1

82-2096

Deck SubAssy, with Insulation

2

23-0955

Condensor

3

30-5884

Fan Shroud

4

04-0504

Screw, 8 - 18 X 0.375

5

23-0982

Dryer/Capillary Assy

6

47-0344

Process Tube

7

06-0031/01 Wiring Diagram, 115V/60Hz Only

-

06-2093

Wiring Diagram, 220v/50-60Hz Only

8

02-0040

Seal

9

02-0114

Compressor Grommet

10

52-0845

Agitator Motor Assy, 115V/60Hz

-

52-0916

Agitator Motor Assy, 220V/50-60Hz

10A 91-0021

Agitator Motor, 115V/60Hz

-

91-0022

Agitator Motor, 220V/50-60Hz

10B 05-0502

Propeller, 2.25 Inch

10C 06-0552/01 Label, 115V/60Hz, 15W
-

06-0661

Label, 220V/50-60Hz, 15W

10D 02-0032

Washer, Rubber

11

47-0607/01 High Side Tube

12

51-0061

Accumulator

13

04-0537

Washer, 0.467 ID X 0.923 OD

14

51-0659/03 Fan Motor Bracket Assy

15

52-1882

Electronic Ice Bank Control, 115V/60Hz
ONLY

-

52-2153

Electronic Ice Bank Control, 220V/50-
60Hz ONLY

16

52-0100

Power Junction Box Assy

17

25-0039

Transformer, 115V/60Hz, 24V, 50VA

-

25-0047

Transformer, 115V/60H, 24V, 75VA

-

25-0048

Transformer, 220V/50-60Hz, 24V, 75VA

18

03-0150

Retainer Clip, Compressor

19

03-0028

Retainer Clip, Evaporator Coil

20

06-0431

Label, 115V/60Hz, 1/4 HP

-

06-0461

Label, 230V/50Hz, 1/4 HP

-

06-0744

Label, 240V/60Hz, 1/4 HP

21

47-0746/02 Low Side Tube

22

04-0237

Screw, 8-32 X .250

23

04-0070

Screw, 10-24 X 1.312

24

50-0268

Insulation Tube

25

52-1897

EIBC Probe Assy, 115V/60Hz ONLY

-

52-2053

EIBC Probe Assy, 220V/50-60Hz ONLY

26

04-0394

Screw, 6 - 32 X 0.500, SS

27

52-0878

Lead Assy, Primary, BLK/WHITE

28

52-0879

Lead Assy, Primary, BLK

29

52-1258

Fan Motor Assy, 115V/60Hz, 9W

-

52-0915

Fan Motor Assy, 220V/50-60Hz, 5W

29A 91-0007

Fan Motor, 115V/60Hz, 9W

-

91-0035

Fan Motor, 220V/50-60Hz, 5W

29B 07-0389

Fan Blade

29C 06-0433/01 Label, 115V/60Hz, 9W
-

06-0725

Label, 230V/50-60Hz, 5W

29D 02-0413

Fan Blade Silencer

29E 04-0060

Fan Blade Nut

12

5.4

COMPRESSOR DECK ASSEMBLY (CONTINUED)

ITEM

PART NO. DESCRIPTION

30

83-0045

Compressor, 115V/60Hz, 1/4
HP

-

83-0047

Compressor, 230V/50Hz, 1/4
HP

-

83-0046

Compressor, 240V/60Hz, 1/4
HP

30A 12-0026

Relay, 115V/60Hz

-

12-0060

Relay, 230V/50Hz

-

12-0252

Relay, 240V/60Hz

30B 12-0150

Overload, 115V/60Hz

-

12-0250

Overload, 230V/50Hz

-

12-0251

Overload, 240V/60Hz

30C 12-0261

Start Capacitor, 240V/60Hz
ONLY

-

- - - - - -

Refrigerant, R134A ONLY,
115V/60Hz, 240V/60Hz - 5.5
Ounces; 230V/50Hz - 5.75
Ounces

31

04-0059

Screw, 8 - 36 X 0.375

32

23-1148

Evaporator Coil Assy

33

52-2004

Harness Assy, EIBC

34

52-2151

Harness Assy, EIBC-
Transformer, 220-240V/50-
60Hz ONLY

Содержание 500 Series

Страница 1: ...IG 4 22 kg cm2 4 14 BAR CARBON DIOXIDE CO2 REQUIREMENTS Minimum pressure of 70 PSIG 4 92 kg cm2 4 83 BAR Maximum pressure of 80 PSIG 5 62 kg cm2 5 52 BAR ICE BANK WEIGHT 16 pounds 17 26 kg WATER BATH...

Страница 2: ...SSOR STARTS BUT DOES NOT SWITCH OFF START WINDING 6 4 15 COMPRESSOR STARTS AND RUNS A SHORT TIME BUT SHUTS OFF ON OVERLOAD 6 4 16 COMPRESSOR AND CONDENSER FAN MOTOR WILL NOT START AFTER FIVE 5 MINUTE...

Страница 3: ...e top grill A Position dispenser on counter B Remove bonnet from the dispenser C Remove insulation strip from in front of refrigeration deck Fill tank with water until water comes out of overflow tube...

Страница 4: ...s and or brix changes B Remove the bonnet and check the level of water in the water bath Replenish as required and replace the bonnet 2 3 MONTHLY A Unplug the dispenser from power source B Remove the...

Страница 5: ...g lever 3 Wearing sanitary gloves remove drain and air dry the nozzle and diffuser 4 Wearing sanitary gloves replace diffuser and twist nozzle into place 5 Draw drinks to flush the chlorine solution f...

Страница 6: ...ounting block or syrup supply and open shutoffs slightly and check water and syrup flow If no flow check dispenser for freeze up or other problems 4 8 Water only dispensed A Water or syrup shutoff on...

Страница 7: ...starting relay Be sure to internal overload use correct relay Failure to use switches compressor off correct relay will cause compressor failure 4 15 Compressor starts and A Dirty condenser A Clean th...

Страница 8: ...S AND WIRING DIAGRAMS 5 1 500 CED WIRING DIAGRAM 220 240V 50 60HZ LANCER ELECTRONIC ICE BANK CONTROL INTERNATIONAL ONLY TROUBLE CAUSE REMEDY 7 WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS...

Страница 9: ...ANCER ICE BANK CONTROL PROBE RELAY FAN MOTOR COMPRESSOR OVERLOAD C M S L M S LABEL WIRING 500 2500 CED 06 0031 01 WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS A FIVE 5 MINUTE DELAY BEFORE...

Страница 10: ...9 4 1 2 22 6 7 8 16 22 11 21 23 24 10 14 12 13 17 3 27 18 15 22 5 24 25 26 16 15 22 19 20 5 3 CABINET ASSEMBLY 9...

Страница 11: ...Splash Plate Extended No Drip Tray 15 51 0494 01 Support Leg 16 81 0112 Leg Adjustable 17 04 0529 Screw 8 32 x 0 750 18 08 0100 Tubing 19 12 0097 Keylock Switch Optional 20 07 0405 Hole Plug Optional...

Страница 12: ...11 2 4 4 7 3 6 5 29E 29B 29D 29C 29A 23 16 22 17 27 28 20 30A 30B 30C 6 30 18 13 9 4 31 14 31 10C 10A 10D 10B 19 8 1 4 24 29 10 21 12 32 26 25 11 15 33 34 5 4 COMPRESSOR DECK ASSEMBLY...

Страница 13: ...9 03 0028 Retainer Clip Evaporator Coil 20 06 0431 Label 115V 60Hz 1 4 HP 06 0461 Label 230V 50Hz 1 4 HP 06 0744 Label 240V 60Hz 1 4 HP 21 47 0746 02 Low Side Tube 22 04 0237 Screw 8 32 X 250 23 04 00...

Страница 14: ...13 NOTES...

Страница 15: ...2666 e mail daniel freser com cn Freser HK Company Ltd Hong Kong Flat A 24 F Houston Industrial Bldg 32 40 Wang Lung Street Tsuen Wan N T Hong Kong Phone 852 2408 2595 FAX 852 2408 2605 e mail freserh...

Страница 16: ...A4 7ER England Phone 44 1895672667 FAX 44 1895637537 e mail court4lancer msn com Hungary H 2100 G d ll Isaszegi t 67 Hungary Phone 36 28 417 179 FAX 36 28416 881 e mail bodolai compuserve com Lancer A...