background image

4.5

Insufficient syrup flow.

A. Insufficient CO

2

pressure to

A. Adjust CO

2

pressure to 80 PSI

BIB pumps.

(5.5 bar) [minimum 70 PSI

(4.8 bar)] for BIB pumps.

B. Shutoff on mounting block not B. Open shutoff fully.

fully open.

C. Foreign debris in syrup flow

C. Remove syrup flow control from

control.

upper body and clean out any

foreign material to ensure smooth

free spool movement.

4.6

Erratic ratio.

A. Incoming water and/or syrup

A. Check pressure and adjust.

supply not at minimum flowing

pressure.

B. Foreign debris in water and/or B. Remove flow controls from upper

syrup flow controls.

body and clean out any foreign

material to ensure smooth free

spool movement.

4.7

No product dispensed.

A. Water and syrup shutoffs on

A. Open shutoffs fully.

mounting block not fully open.

B. The key switch on an electric

B. Turn key switch to ON position.

valve is in the OFF position.

C. Cup lever arm or ID panel

C. Repair.

actuator on electric valve is not

actuating the switch.

D. Electric current not reaching

D. Check electric current supplied to

Valve.

valve.  If current is adequate, check

solenoid coil and switch, and

replace if necessary.

E. Improper or inadequate water

E. Remove valve from mounting block

or syrup supply.

and open shutoffs slightly and

check water and syrup flow.  If no

flow, check dispenser for freeze-up

or other problems.

4.8

Water only dispensed;

A. Water or syrup shutoff on

A. Open shutoff fully.

no syrup; or syrup only

mounting block not fully open.

dispensed, no water.

B. Improper or inadequate water

B. Remove valve from mounting block,

or syrup flow.

open shutoffs slightly and check

water and syrup flow.  If no flow

check dispenser for freeze-up or

other problems.  Ensure BIB

connection is engaged.

C. Kinked line.

C. Remove kink or replace line.

4.9

Valve will not shut off.

A. Cup lever may be sticking or

A. Correct or replace lever.

binding.

B. Switch not actuating freely.

B. Check switch for free actuation.

C. Solenoid armature not

C. Replace defective armature or

returning to bottom position.

spring.

4.10 Excessive foaming.

A. Incoming water or syrup

A. Correct prior to dispenser.

temperature too high.

Consider larger dispenser or

precooler.

B. Water flow rate too high.

B. Readjust and reset ratio.  Refer to

Sections 1.5.K and 1.5.L.

C. Nozzle and diffuser not

C. Remove and reinstall properly.

properly installed.

D. Nozzle and diffuser not clean.

D. Remove and clean.

E. Air in BIB lines.

E. Bleed air from BIB lines.

F. Poor quality ice.

F. Check quality of ice used in drink.

G. High beverage temperature.

G. Check refrigeration system.

5

TROUBLE

CAUSE

REMEDY

Содержание 500 Series

Страница 1: ...IG 4 22 kg cm2 4 14 BAR CARBON DIOXIDE CO2 REQUIREMENTS Minimum pressure of 70 PSIG 4 92 kg cm2 4 83 BAR Maximum pressure of 80 PSIG 5 62 kg cm2 5 52 BAR ICE BANK WEIGHT 16 pounds 17 26 kg WATER BATH...

Страница 2: ...SSOR STARTS BUT DOES NOT SWITCH OFF START WINDING 6 4 15 COMPRESSOR STARTS AND RUNS A SHORT TIME BUT SHUTS OFF ON OVERLOAD 6 4 16 COMPRESSOR AND CONDENSER FAN MOTOR WILL NOT START AFTER FIVE 5 MINUTE...

Страница 3: ...e top grill A Position dispenser on counter B Remove bonnet from the dispenser C Remove insulation strip from in front of refrigeration deck Fill tank with water until water comes out of overflow tube...

Страница 4: ...s and or brix changes B Remove the bonnet and check the level of water in the water bath Replenish as required and replace the bonnet 2 3 MONTHLY A Unplug the dispenser from power source B Remove the...

Страница 5: ...g lever 3 Wearing sanitary gloves remove drain and air dry the nozzle and diffuser 4 Wearing sanitary gloves replace diffuser and twist nozzle into place 5 Draw drinks to flush the chlorine solution f...

Страница 6: ...ounting block or syrup supply and open shutoffs slightly and check water and syrup flow If no flow check dispenser for freeze up or other problems 4 8 Water only dispensed A Water or syrup shutoff on...

Страница 7: ...starting relay Be sure to internal overload use correct relay Failure to use switches compressor off correct relay will cause compressor failure 4 15 Compressor starts and A Dirty condenser A Clean th...

Страница 8: ...S AND WIRING DIAGRAMS 5 1 500 CED WIRING DIAGRAM 220 240V 50 60HZ LANCER ELECTRONIC ICE BANK CONTROL INTERNATIONAL ONLY TROUBLE CAUSE REMEDY 7 WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS...

Страница 9: ...ANCER ICE BANK CONTROL PROBE RELAY FAN MOTOR COMPRESSOR OVERLOAD C M S L M S LABEL WIRING 500 2500 CED 06 0031 01 WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS A FIVE 5 MINUTE DELAY BEFORE...

Страница 10: ...9 4 1 2 22 6 7 8 16 22 11 21 23 24 10 14 12 13 17 3 27 18 15 22 5 24 25 26 16 15 22 19 20 5 3 CABINET ASSEMBLY 9...

Страница 11: ...Splash Plate Extended No Drip Tray 15 51 0494 01 Support Leg 16 81 0112 Leg Adjustable 17 04 0529 Screw 8 32 x 0 750 18 08 0100 Tubing 19 12 0097 Keylock Switch Optional 20 07 0405 Hole Plug Optional...

Страница 12: ...11 2 4 4 7 3 6 5 29E 29B 29D 29C 29A 23 16 22 17 27 28 20 30A 30B 30C 6 30 18 13 9 4 31 14 31 10C 10A 10D 10B 19 8 1 4 24 29 10 21 12 32 26 25 11 15 33 34 5 4 COMPRESSOR DECK ASSEMBLY...

Страница 13: ...9 03 0028 Retainer Clip Evaporator Coil 20 06 0431 Label 115V 60Hz 1 4 HP 06 0461 Label 230V 50Hz 1 4 HP 06 0744 Label 240V 60Hz 1 4 HP 21 47 0746 02 Low Side Tube 22 04 0237 Screw 8 32 X 250 23 04 00...

Страница 14: ...13 NOTES...

Страница 15: ...2666 e mail daniel freser com cn Freser HK Company Ltd Hong Kong Flat A 24 F Houston Industrial Bldg 32 40 Wang Lung Street Tsuen Wan N T Hong Kong Phone 852 2408 2595 FAX 852 2408 2605 e mail freserh...

Страница 16: ...A4 7ER England Phone 44 1895672667 FAX 44 1895637537 e mail court4lancer msn com Hungary H 2100 G d ll Isaszegi t 67 Hungary Phone 36 28 417 179 FAX 36 28416 881 e mail bodolai compuserve com Lancer A...

Отзывы: