Cleaning and Sanitizing Syrup Lines - Bag in Box
Cleaning and Sanitizing Ice Bin Compartment
1. Disconnect syrup lines from BIB’s
2. Place syrup lines, with BIB connectors, in a bucket of warm
water.
3. Activate each valve to fill the lines with warm water and flush
out syrup remaining in the lines.
4. Prepare Cleaning Solution described above.
5. Place syrup lines, with BIB connectors, into cleaning
solution.
6. Activate each valve until lines are filled with cleaning
solution then let stand for ten (10) minutes.
7. Flush out cleaning solution from the syrup lines using clean,
warm water.
1. Prepare cleaning solution and sanitizing solution according
to the corresponding sections on the previous page.
2. Using the cleaning solution and a clean soft cloth, wash
down the sides of the ice bin and the surface of the
aluminum casting.
3. Using clean, potable water, thoroughly rinse away the
cleaning solution from the sides and surface of the casting.
Following sanitation, rinse with end-use product until
there is no aftertaste. Do not use a fresh water rinse.
This is a NSF requirement. Residual sanitizing solution
left in the system creates a health hazard.
!
CAUTION
8. Prepare Sanitizing Solution described above.
9. Place syrup lines into sanitizing solution and activate each
valve to fill lines with sanitizer. Let sit for ten (10) minutes.
10. Reconnect syrup lines to BIB’s and draw drinks to flush solu-
tion from the dispenser.
11. Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
Cleaning and Sanitizing Nozzles
Following sanitation, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
!
CAUTION
1. Disconnect power, so as to not activate valve while cleaning.
2. Remove merchandiser to reveal valves.
3. Remove nozzle by twisting counter clockwise and pulling
down.
4. Remove diffuser by pulling down.
5. Rinse nozzle and diffuser with warm water.
6. Wash nozzle and diffuser with cleaning solution then
immerse in sanitizing solution and let sit for fifteen (15)
minutes.
7. Set nozzle and diffuser aside and let air dry.
DO NOT
rinse
with water after sanitizing.
8. Reconnect diffuser and nozzle.
9. Connect power.
10. Taste the drink to verify that there is no off-taste. If off-taste
is found, flush syrup system again.
A
B
C
A. Nozzle
B. Diffuser
C. Soda Lever
4. Using plastic sanitary gloves, soak a white cotton gauze
cleaning rag in the sanitizing solution and wipe all surfaces
in the ice compartment.
The ice bin compartment of the dispenser should be
thoroughly cleaned and sanitized at least once every
month.
NOTE
5. Sanitizing of the ice compartment is complete. Refill with ice.
A fresh water rinse cannot follow sanitation of
equipment. Purge only with the end use product. This is
an NSF requirement.
!
CAUTION
Содержание 2200 Series
Страница 24: ...24 Series 2300 Drop In Pre Mix 28 27 23 20 26 18 17 25 16 11 15 10 7 6 5 3 2 1 24 22 14 12 13 19 21 8 9 4...
Страница 30: ...30 16 15 5 1 20 17 11 9 8 7 12 14 13 18 19 10 6 3 4 2 Series 23300 Drop In...
Страница 39: ...39 2300 8 Valve 2300 10 Valve 2300 PI 6 Valve 3 2 1...
Страница 42: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...