4. Route tubing from the remote carbonator to one of the low
pressure CO
2
regulator manifold outlets.
5. Route tubing routed from the syrup pumps to the second
outlet of the low pressure CO
2
regulator manifold.
DO NOT TURN ON CO
2
SUPPLY AT THIS TIME
!
WARNING
A. CO
2
Regulator
B. Screwdriver
C. Loosened Lock Nut
D. Regulator Adjustment
Screw
A
B
C
D
A
B
C
D
A. Line to Carbonator
B. Line to Syrup Pumps
C. Line to CO
2
Regulator
D. CO
2
Regulator Manifold
6. Using a wrench, loosen lock nut on the regulator adjustment
screw of the high pressure CO
2
regulator connected to the
source, then using a screwdriver back out lock nut screw all
the way.
7. Repeat Step 6 for both low pressure CO
2
regulators on the
regulator manifold routed to the carbonator and the syrup
pumps.
1. Install syrup pumps and syrup containers in designated
location. Attach CO
2
line from the low pressure regulator to
syrup pumps.
2. Attach CO
2
line from the low pressure regulator to gas inlet
of remote carbonator.
3. Turn on water source.
4. Open the pressure relief valve, located on the remote
carbonator, by flipping up on the valve cap lever. Hold open
until water flows from the relief valve then close (flip down)
the relief valve.
5. Verify all Bag-In-Box contains syrup and check all
connections for leaks.
6. Place enough ice in the ice bin to fill approximately 1/2 of the
bin before plugging in the unit.
7. Connect unit power cord to grounded electrical outlet.
Failure to disconnect the motor power supply will
damage the carbonator motor, the pump and void the
warranty.
!
ATTENTION
The dispenser must be properly electrically grounded
to avoid serious injury or fatal electrical shock. The
power cord has a three-prong grounded plug. If a
three-hole grounded electrical outlet is not available,
use an approved method to ground the unit. Follow all
local electrical codes when making connections. Each
dispenser must have a separate electrical circuit. Do
not use extension cords. Do not connect multiple
electrical devices on the same outlet.
!
WARNING
8. Activate each valve to ensure a good flow of water is
achieved.
9. Ensure pump deck is turned OFF before turning on CO
2
.
A. Regulator Adjustment Screw
B. Adjust to 110 PSI (0.758 MPA)
C. Wrench
A
B
C
11. Adjust both of the low pressure regulators on the regulator
manifold to 75 PSI (0.517 MPA) then tighten locknut with
wrench.
12. Activate each valve until gas-out.
13. Plug in the remote carbonator pump deck, if not already
done so, and turn the switch to the ON position.
14. Activate each valve until the carbonator pump comes on.
Release the button, allow carbonator to fill and stop. Repeat
this process until a steady flow of carbonated water is
achieved.
15. Activate each valve to purge air from the syrup lines.
The pump deck has a 3 minute timeout feature. If the
timeout occurs, turn the deck OFF then ON by flipping
the switch on the control box.
NOTE
To check for CO
2
leaks, close the valve on the CO
2
cylinder and observe if the pressure to the system
drops with the cylinder valve closed for five minutes.
Open the cylinder valve after check.
NOTE
10. Turn on CO
2
at the source then, using a screwdriver, adjust
the high pressure regulator at the source to 110 PSI (0.758
MPA) then tighten locknut with wrench.
Dispenser Setup
Содержание 2200 Series
Страница 24: ...24 Series 2300 Drop In Pre Mix 28 27 23 20 26 18 17 25 16 11 15 10 7 6 5 3 2 1 24 22 14 12 13 19 21 8 9 4...
Страница 30: ...30 16 15 5 1 20 17 11 9 8 7 12 14 13 18 19 10 6 3 4 2 Series 23300 Drop In...
Страница 39: ...39 2300 8 Valve 2300 10 Valve 2300 PI 6 Valve 3 2 1...
Страница 42: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...