General Information
CLEANING AND SANITIZING
•
Lancer equipment (new or reconditioned) is shipped from the factory cleaned and sanitized in accordance with NSF guidelines.
The operator of the equipment must provide continuous maintenance as required by this manual and/or state and local health
department guidelines to ensure proper operation and sanitation requirements are maintained.
The cleaning procedures provided herein pertain to the Lancer equipment identified by this manual. If other equipment
is being cleaned, follow the guidelines established by the manufacturer for that equipment.
NOTE
•
Cleaning should be accomplished only by trained personnel. Sanitary gloves are to be used during cleaning operations. Applicable
safety precautions must be observed. Instruction warnings on the product being used must be followed.
• Use sanitary gloves when cleaning the unit and observe all applicable safety precautions.
• DO NOT
use a water jet to clean or sanitize the unit.
• DO NOT
disconnect water lines when cleaning and sanitizing syrup lines, to avoid contamination.
• DO NOT
use strong bleaches or detergents; These can discolor and corrode various materials.
• DO NOT
use metal scrapers, sharp objects, steel wool, scouring pads, abrasives, or solvents on the dispenser.
• DO NOT
use hot water above 140° F (60° C). This can damage the dispenser.
• DO NOT
spill sanitizing solution on any circuit boards. Insure all sanitizing solution is removed from the system.
!
ATTENTION
Cleaning and Sanitizing Solutions
Cleaning Solution
Mix a mild, non-abrasive detergent (e.g. Sodium Laureth Sulfate,
dish soap) with clean, potable water at a temperature of 90°F to
110°F (32°C to 43°C). The mixture ratio is one ounce of
cleaner to two gallons of water. Prepare a minimum of five
gallons of cleaning solution. Do not use abrasive cleaners or
solvents because they can cause permanent damage to the unit.
Ensure rinsing is thorough, using clean, potable water at a
temperature of 90°F to 110°F. Extended lengths of product lines
may require additional cleaning solution.
Sanitizing Solution
Prepare the sanitizing solution in accordance with the
manufacturer’s written recommendations and safety guidelines.
The type and concentration of sanitizing agent recommended in
the instructions by the manufacturer shall comply with 40 CFR
§180.940. The solution must provide 100 parts per million (PPM)
chlorine (e.g. Sodium Hypochlorite or bleach) and a minimum of
five gallons of sanitizing solution should be prepared.
If a powder sanitizer is used, dissolve it thoroughly with hot water prior to adding to the syrup system. Ensure
sanitizing solution is removed from the dispenser as instructed. Avoid getting sanitizing solution on circuit boards. Do
not use strong bleaches or detergents; these can discolor and corrode various materials. Do not use metal scrapers,
sharp objects, steel wool, scouring pads, abrasives, or solvents on the dispenser. Do not use hot water above 140° f
(60° c). This can damage the dispenser.
!
WARNING
Содержание 2200 Series
Страница 24: ...24 Series 2300 Drop In Pre Mix 28 27 23 20 26 18 17 25 16 11 15 10 7 6 5 3 2 1 24 22 14 12 13 19 21 8 9 4...
Страница 30: ...30 16 15 5 1 20 17 11 9 8 7 12 14 13 18 19 10 6 3 4 2 Series 23300 Drop In...
Страница 39: ...39 2300 8 Valve 2300 10 Valve 2300 PI 6 Valve 3 2 1...
Страница 42: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...