Structure and function 3
Issue EN 2022/05 PUK 6 Operating manual
23/56
The type plate shows the most important technical data for the device.
The bus connection enables external control of the device via bus control.
The USB port is used to update the device software via USB data carrier.
The LAN connection is used for device diagnostics. This can be done by a
technician.
The mains switch can be used to disconnect the device from the power sup-
ply.
The device fuse is located in the fuse compartment.
The mains cable supplied is connected to the mains socket.
The gas connection allows the connection of argon inert gas. The gas hose
must have a diameter of 6.0 mm and may carry a maximum pressure of 4
bar.
The ventilation opening is used for air circulation and cooling of heat-sensi-
tive electronic components inside the device.
The permissible mains voltage for the device is marked with a red dot-
shaped marking and must not be exceeded.
A foot switch with M12 connection can be connected to this socket.
A Lampert electrode grinding motor from the accessories range can be con-
nected to this socket.
A Lampert eye protection system from the accessories range can be con-
nected to this socket.
The hazard warnings indicate the hazards that can potentially arise from the
device.
Type plate
Bus connection
USB connection
LAN connection
Mains switch
Fuse compartment
IEC-60320 C14 socket
Gas connection
Ventilation opening
Mains voltage approved
for this device
Connection socket for
foot switch
Connection socket for
electrode grinding motor
Connection socket for eye
protection system
Hazard warnings