Installing your cooker hood                                                                           

You will have to decide before installing your cooker hood whether to use it in extraction mode or 

recirculation mode. 

1.  We recommend that at least two people install 

this hood.

2.  Cut a rectangular aperture in the canopy unit 

475mm wide X 275mm 14mm from the front 

edge  

3.  If the extractor is to be ducted out, ensure that 

it is possible to connect the ducting hose.

4.  If the extractor is to be used in recirculation 

mode, ensure that the canopy allows the 

recirculating air to be circulated from the top 

of the extractor and canopy.

5. 

Remove the grease filter ‘A’ as described 

Previously.

6.  Remove the four screws securing the extractor 

frame ‘B’ to the extractor body.

7.  If the extractor is to be ducted out, connect the 

extractor to the vent hose.

8.  With the help of an assistant introduce the 

extractor into the opening cut into the canopy 

housing, taking care not to trap the ducting 

hose or the mains cable, and secure with the 

wood screws provided.

9.  Replace the extractor frame and the four 

screws removed earlier from the extractor.

Connecting to external ducting                                                                      

• 

Connect the coupling to the top or the rear of the cooker hood, and then connect a 125 mm ducting 

hose to the coupling (please note that the ducting hose is not supplied with the appliance). 

• 

You may find an anti-draft flap included with the fixtures and fittings for the cooker hood. 

• 

The other end of the ducting hose should be connected to a discharge outlet that is suitable for 

cooking vapours. It should have a cross section of at least 150 cm².

• 

The maximum distance between the coupling and your discharge outlet should be 3 metres, with one 

90 degree bend

.

495mm

275mm

14mm

A)

B)

Содержание LAM2300

Страница 1: ...User Installation Guide LAM2300 60cm Canopy Extractor...

Страница 2: ...possible hazards to health and property Warning possibility of electric shock This product s packaging material is recyclable Help recycle it and protect the environment by dropping it off in the mun...

Страница 3: ...out 06 Control Panel Layout 06 Using Your Cooker Hood 07 General Cleaning 07 Care and maintenance 08 General Cleaning 08 Grease Filters 08 Carbon Filters 09 Replacing the Lamps 09 Installation 10 Meth...

Страница 4: ...ash down the product with excessive water as there is the risk of electric shock Never use the product when your judgment or coordination is impaired by the use of alcohol and or drugs Product must be...

Страница 5: ...re that pans are always on hobs when burners are lit Remember that when in extraction mode your cooker hood is removing air from your room Ensure that proper ventilation measures are being observed Fi...

Страница 6: ...off 0 Low speed I Medium Speed II High Speed III 3 4 5 3 6 1 2 7 8 Dimensions Extractor width 525mm Extractor depth 275mm Extractor height 162mm Not including vent adapter Required aperture 495mm wide...

Страница 7: ...cook or at the very least when you begin cooking You should also run your hood for ten minutes after you have finished cooking This process must be followed before the cooker hood is used for the fir...

Страница 8: ...ime the grease filter may become a fire risk if the greasy residue is allowed to build up To prevent a fire hazard the grease filter should be cleaned Depending on use this should be done every 10 15...

Страница 9: ...and twist anticlockwise from below to release Insert the new 40W type GU10 lamp and twist clockwise from below to engage the bayonet pins If the light still does not work make sure that the bulb is in...

Страница 10: ...e already operating unless perfect ventilation can be guaranteed Connect the external ducting kit to the outlet of the extractor Charcoal filters are not required if the extractor is to be ducted out...

Страница 11: ...ect a ducting hose to the outside Carry out all necessary masonry work prior to the fitting of the cooker hood and cabinetry Ensure that all electrical connections are carried out by a suitably qualif...

Страница 12: ...ucted out connect the extractor to the vent hose 8 With the help of an assistant introduce the extractor into the opening cut into the canopy housing taking care not to trap the ducting hose or the ma...

Страница 13: ...e terminology DOUBLE POLE means that both the live and neutral supplies are switched and disconnected at the same time The terminations labelled SUPPLY are the connections for the internal house wirin...

Страница 14: ...filters The extractor works normaly but smells linger Clogged filters can reduce the product s efficiency and may cause unwanted smells Clean the grease filters with warm water and mild detergent and...

Страница 15: ...correctly installed and operated in accordance with the manufacturer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alternations which...

Страница 16: ...Z If supplied please stick your self adhesive product rating plate here or make a note of the product serial number below in the box below for future reference Serial Number Issue 09 2014...

Отзывы: