User manual LAM2300

Do not set your cooker hood less than 

700mm above your cooker.

• 

When installed between adjoining wall 

cabinets, the cabinets must not overhang the 

hob.

• 

The edges of the cooker hood may be sharp 

– be mindful of this as you handle your 

appliance, especially during installation and 

cleaning.

 

Do not clean behind the grease filter!

• 

If the room where the cooker hood is to be 

used contains a fuel burning appliance such 

as a central heating boiler then its flue must 

be of the sealed or balanced flue type.

• 

If other types of flue or appliances are fitted, 

ensure that there is an adequate supply of air 

in the room.

• 

When the hood is being used in extraction 

mode, ensure that the ducting is fire retardant 

and that there are no bends greater  than 90 

degrees as this will reduce the efficiency of 

the hood.

• 

Ensure the ducting for the extractor mode has 

the same diameter as the outlet hole all the 

way through.

• 

Always put lids on pans and ensure that pans 

are always on hobs when burners are lit.

• 

Remember that when in extraction mode, your 

cooker hood is removing air from your room.  

Ensure that proper ventilation measures are 

being observed. 

Fire Safety    

               

When installing the hood, ensure that the 

following recommended distances are observed 

between the highest point on the hob top 

(including the burners) and the bottom of the 

cooker hood:

Electric cookers: 

700 mm

Gas cookers: 

700 mm

Coal / oil cookers:  800 mm

• 

Never flambé cook under this cooker hood.

• 

Dirty cooking oil is an even greater fire risk.

• 

Do not install above a cooker with a high level 

grill.

Safety for children   

               

• 

Electrical products can be dangerous to 

children. Keep children away from the product 

when it is operating and do not allow them to 

play with or near the product.

• 

The packaging materials will be dangerous for 

children. Keep the packaging materials away 

from children. Please dispose of all parts of 

the packaging according to environmental 

standards.

Safety when working with 
electricity 

 

                    

• 

In case of any damage, switch off the product 

and disconnect it from the mains. To do this, 

turn off the fuse at the fuse box.

• 

Make sure that fuse rating is compatible with 

the product.

Содержание LAM2300

Страница 1: ...User Installation Guide LAM2300 60cm Canopy Extractor...

Страница 2: ...possible hazards to health and property Warning possibility of electric shock This product s packaging material is recyclable Help recycle it and protect the environment by dropping it off in the mun...

Страница 3: ...out 06 Control Panel Layout 06 Using Your Cooker Hood 07 General Cleaning 07 Care and maintenance 08 General Cleaning 08 Grease Filters 08 Carbon Filters 09 Replacing the Lamps 09 Installation 10 Meth...

Страница 4: ...ash down the product with excessive water as there is the risk of electric shock Never use the product when your judgment or coordination is impaired by the use of alcohol and or drugs Product must be...

Страница 5: ...re that pans are always on hobs when burners are lit Remember that when in extraction mode your cooker hood is removing air from your room Ensure that proper ventilation measures are being observed Fi...

Страница 6: ...off 0 Low speed I Medium Speed II High Speed III 3 4 5 3 6 1 2 7 8 Dimensions Extractor width 525mm Extractor depth 275mm Extractor height 162mm Not including vent adapter Required aperture 495mm wide...

Страница 7: ...cook or at the very least when you begin cooking You should also run your hood for ten minutes after you have finished cooking This process must be followed before the cooker hood is used for the fir...

Страница 8: ...ime the grease filter may become a fire risk if the greasy residue is allowed to build up To prevent a fire hazard the grease filter should be cleaned Depending on use this should be done every 10 15...

Страница 9: ...and twist anticlockwise from below to release Insert the new 40W type GU10 lamp and twist clockwise from below to engage the bayonet pins If the light still does not work make sure that the bulb is in...

Страница 10: ...e already operating unless perfect ventilation can be guaranteed Connect the external ducting kit to the outlet of the extractor Charcoal filters are not required if the extractor is to be ducted out...

Страница 11: ...ect a ducting hose to the outside Carry out all necessary masonry work prior to the fitting of the cooker hood and cabinetry Ensure that all electrical connections are carried out by a suitably qualif...

Страница 12: ...ucted out connect the extractor to the vent hose 8 With the help of an assistant introduce the extractor into the opening cut into the canopy housing taking care not to trap the ducting hose or the ma...

Страница 13: ...e terminology DOUBLE POLE means that both the live and neutral supplies are switched and disconnected at the same time The terminations labelled SUPPLY are the connections for the internal house wirin...

Страница 14: ...filters The extractor works normaly but smells linger Clogged filters can reduce the product s efficiency and may cause unwanted smells Clean the grease filters with warm water and mild detergent and...

Страница 15: ...correctly installed and operated in accordance with the manufacturer s instructions and used for normal domestic purposes This guarantee does not cover accidental damage misuse or alternations which...

Страница 16: ...Z If supplied please stick your self adhesive product rating plate here or make a note of the product serial number below in the box below for future reference Serial Number Issue 09 2014...