23
Instructions and Installation
For liquid gas (cylinder gas)
use pressure regulators which
comply with the relevant
national standards.
Use only pipes, washers and
sealing washers which comply
with relevant national standards.
For some models a conic link
is supplied for the installation in
the countries where this type of
this link is obligatory: in the image
below it is pointed out how to
recognise the different of links
(CY= cylindrical, CO= conic).
In every case the cylindrical part
of the link has to be connected
to the hob.
When connecting the hob to the
gas supply using semi-rigid hoses
please ensure that the maximum
distance covered by the hose
does not exceed two metres.
Adapting the hob to
different types of gas
To adapt the hob for use with
different types of gas, carry out
the following instructions:
Unscrew the injector and replace
it with one suitable for the gas to
be used.
• Remove the grids and burners.
• Insert an hexagonal spanner
(7mm) into the burner support.
• Unscrew the injector and
replace it with one suitable
for the gas to be used,
(see page 27).
Cylindrical
Conical
NOTICE:
If the gas type of
the unit is changed, then the
rating plate that shows the
gas type of the unit must also
be changed.