49
Statistics
The statistics menu displays some of the module's historical data.
A
To access to this menu, press and hold
for 5 seconds.
B
Use
to go to the next parameter in the statistics menu.
Information
The treated water display scrolls to allow more than 9999 litres to be displayed.
Information
When the variable brining function
Vb
(brining option) is disabled (i.e. with OFF
status) all optimisation values E:xx are set to E:00.
Information
It only shows the time and date of the last regeneration if regenerations have been
carried out.
Information
While the statistics are displayed, the regeneration icon is on, if not otherwise
indicated.
Data
Description
1 xxxx
Number of regenerations carried out.
2 SAxx
Number of regenerations remaining before triggering the salt alarm.
3 FFxx
Number of days elapsed since the last regeneration.
4 M3xxxxxx.xx
Treated water in m
3
.
5 Hxxxxx
Number of hours elapsed since first installation.
6 LMxxxx
Average consumption since first installation in L/h.
7 P OFF/ON
Sensor presence: OFF or ON.
8* Xx:xx
Time and date of previous regenerations.
9*
M xx
01
Regeneration was launched in instantaneous manual mode.
02
Regeneration was launched in delayed manual mode at the programmed
time.
A xx
01
Automatic regeneration launched in timed mode (SH:00).
02
Automatic regeneration launched in combined mode (SH:01) because
volume exhausted.
03
Automatic regeneration launched in combined mode (SH:01) because
maximum number of days for obligatory regeneration has been
reached.
04
-