45
To gain access to the PHASE number press the MODE button once (an indicator light to the right of the 1
st
figure comes on). Press STEP to display all the available PHASES.
LIST OF PARAMETERS INDICATED BY 1
st
FIGURE ON DISPLAY (Values can be adjusted by the user).
Example:
indicator light
Step n
°
display
Parameter value
displayi
2
Phase n
°
Parameter
Value range
00 = domestic hot water
excluded
01 = 5
°
C hyst pump
continuously on Hot water
02 = 5
°
C hysteresis
03 = 10
°
C hysteresis
04 = 20
°
C hysteresis
05 = 30
°
C hysteresis
1
Hot water temperature
from 60 to 90
°
C
02
Hot water system
00 = heating disabled
01 = heating enabled
02 = heating enabled, pump
running continuously
01
3
Heating
4
80
settable minimum 55
°
C
Water delivery temperature
from 20 to 90
°
C
80
Default settings
To exit the PHASE list press twice.
60
CONEXIÓN HIDRÁULICA
Fijen la plantilla de montaje apoyándola a la pared y a continuación procedan con la aplicación de todas las
tuberías: ida instalación, retorno instalación, agua fría, agua caliente y si fuera necesario también la tubería
del gas y la alimentación de la línea eléctrica con termostato ambiente.
Una vez puestas las tuberías se pueden desenroscar los racores terminales y meter tapones normales cerrados
para efectuar la prueba hidráulica de la instalación.
DESCRIPCIÓN
C
Agua caliente Ø 1/2”
G
Gas Ø 3/4”
F
Agua alimentación caldera Ø 1/2” (fría)
AE
Alimentación eléctrica
M
Ida instalación Ø 3/4”
R
Retorno instalación Ø 3/4”
NOTA: Preparar piezas hidráulicas de unión hembra
Kit conexiones hidráulicas
confort (bajo pedido)