WATER SUPPLY CONNECTION
Fit the assembly template up against the wall. Then fit all the piping: system delivery, system return, cold water,
hot water and (where required) gas and electrical power supply for the room thermostat.
Once the pipes have been fitted the end fittings can be unscrewed and ordinary plugs can be inserted ready
for water supply tests to be carried out.
LEGEND
C
Hot water Ø 1/2"
G
Gas Ø 3/4”
F
Boiler water supply Ø 1/2" (cold)
AE
Electrical supply
M
System delivery Ø 3/4"
R
System return Ø 3/4"
NOTE: Preview hydraulic female connections.
Comfort water supply connection
kit (available on request)
69
Para acceder al número de la FASE hay que presionar una vez el botón MODE (aparece un punto luminoso
fijo a la derecha de la 1
a
cifra). Presionar el botón STEP para visualizar todas las FASES disponibles.
LISTA DE LAS FASES INDICADAS POR LA PRIMERA CIFRA DE LA PANTALLA (Valores que puede modificar el usuario)
Ejemplo:
punto luminoso fijo
pantalla
n
°
fase
pantalla valor
parámetros
2
N
°
fase
Parámetro
Campo de valores
00 = agua caliente sanitaria
desconectada
01 = 5
°
C histéresis + bomba conti-
nuamente en el circ. sanitario
02 = 5
°
C de histéresis
03 = 10
°
C de histéresis
04 = 20
°
C de histéresis
05 = 30
°
C de histéresis
1
Temperatura agua sanitaria
de 60 a 90
°
C
02
Sistema agua caliente sanitaria
00 = calefacción desactivada
01 = calefacción activada
02 = calefacción activada y bom-
ba que funciona continua-
mente
01
3
Calefacción
4
80
mínimo programable 55
°
C
Temperatura de ida
de 20 a 90
°
C
80
Valores programados
(default)
Para abandonar el programa LISTA DE FASES hay que presionar dos veces