ATTENTION: Use only air intake/ fumes evacuation kits produced by Lamborghini Caloreclima.
FLUE EXHAUST INSTALLATION
CONCENTRIC FLUE PIPE
Fit the concentric elbow pipe positioning it in the desired direction and insert the sealing gasket on it. Fit the air
intake and flue pipes, observing the distances indicated on the installation diagram. The flue pipe should slope
slightly outward.
DOUBLE FLUE PIPE
CONCENTRIC FLUE EXHAUST: max length 3 m
DOUBLE FLUE PIPE-BANOX 24
( Delivery): max length 58 m.
DOUBLE FLUE PIPE-BANOX 28
( Delivery): max length 50 m.
Installing an elbow to connect the boiler to the chimney will cause a
drop in pressure.
The values set out in the table below indicate the necessary reduction
to the length of the linear pipes.
TYPE OF
INSTALLATION
CONCENTRIC
FLUE EXHAUST
DOUBLE FLUE PIPE
(INTAKE/EXHAUST)
90
°
ELBOW
FITTED
1 mt.
0,6 mt.
45
°
ELBOW
FITTED
0,5 mt.
0,3 mt.
64
ESQUEMA DE MONTAJE
DESCRIPCIÓN
CiR
Circulador instalación
PSG
Presostato de seguridad gas
PA
Presostato aire
PH2O
Presostato agua
E.A.
Electrodo de encendido
E.R.
Electrodo de detección
TRA
Transformador
IG
Interruptor general
VG
Válvula gas 1-2
M1
Regleta de bornes pa27
VD
Válvula de 3 vías
E/I
Selector verano/invierno
TA
Termostato ambiente
TB
Termostato acumulador
SE
Sonda exterior
SR
Sonda retorno
SM
Sonda ida
VN
Ventilador
X2
Conector amp. 13 vías
X3
Conector amp. 6 vías
X4
Conector amp. 2 vías
X7-X8
Conector conexión ordenador
3AT
Fusible 3A (electroventilador)
2AF
Fusible 2A (circuitos 24 V)
2AF(F1)
Fusible alimentación 230 V (2A)
CL
Cable línea 230 V 50 Hz
C
Conector Wieland
FA
Filtro antiparasitario
Para conectar el termostato ambiente TA hay que quitar el puente
1-2
de la regleta de bornes
M1
.