Vega Customer Applications Manual
Section 2 - Analogue Primary Options
Rev. A3: October 2003
Page 9 of 48
5V Auxiliary supply.
This is available for powering auxiliary circuits and is present when AC input is applied regardless of inhibit/enable state of the
PSU outputs. The output is rated as SELV.
Output voltage
5V +/- 5% (Option E, F, EV, FV) or 5-15V (Option xEW, xFW)
Max continuous output current
100 mA (Option E, F) or 300mA (Option EV, FV) or 1A (Option xEW, xFW)
Overload protection
Current limited and thermally protected
Hold up time
1 Sec minimum
Isolation to earth
500V DC max
Or ‘ENABLE’
Either ‘INHIBIT’
Global Inhibit Logic 0
Pin 5 to be taken to 0-0.8V to
turn outputs off, otherwise
outputs normally on
2 – 5V
0 – 0.8V
Global Inhibit Logic 1
Pin 6 to be taken to 2 – 5V to
turn outputs off, otherwise
outputs normally on
0 – 0.8V
2 – 5V
OUTPUTS ON OUTPUTS OFF
OUTPUTS ON OUTPUTS OFF
Global Enable Logic 0
Pin 5 to be taken to 0 – 0.8V
to turn outputs on, otherwise
outputs normally off
Global Enable Logic 1
Pin 6 to be taken to 2 – 5V
to turn outputs on, otherwise
outputs normally off
0 – 0.8V
2 – 5V
OUTPUTS ON OUTPUTS OFF
OUTPUTS ON OUTPUTS OFF
2 – 5V
0 – 0.8V
Содержание V4FFS 12V12A
Страница 22: ...Vega Customer Applications Manual Section 6 Vega Outline Drawings Rev A3 October 2003 Page 22 of 48...
Страница 23: ...Vega Customer Applications Manual Section 6 Vega Outline Drawings Rev A3 October 2003 Page 23 of 48...
Страница 24: ...Vega Customer Applications Manual Section 6 Vega Outline Drawings Rev A3 October 2003 Page 24 of 48...
Страница 25: ...Vega Customer Applications Manual Section 6 Vega Outline Drawings Rev A3 October 2003 Page 25 of 48...
Страница 26: ...Vega Customer Applications Manual Section 6 Vega Outline Drawings Rev A3 October 2003 Page 26 of 48...