Vega Customer Applications Manual
Section 10 - Combining Modules
Rev. A3: October 2003
Page 35 of 48
Tables of Common module combinations.
This table shows the most commonly used series combinations that are available.
Module
name
How done
Vmin
Vmax
Imax
Slots
Power @
Vmin
Power @
Vmax
EE2
E2 + E2
7.6
16
55
4
418
880
CC3
C3 + C3
18.2
32.4
18
2
327.6
583.2
HH5/3
Both halves of H5/3
25.3
47.2
5
1
126.5
236
BB4
B4 + B4
32.6
43
10
2
326
430
DD4
D4 + D4
28
43
18
3
504
774
HH5/4
Both halves of H5/4
32.5
56
4.5
1
146.2
252
C5B4
C5 + B4
43
48
10
2
430
480
CC5
C5 + C5
48.1
62
10
2
481
620
DD5
D5 + D5
42
56
15
3
630
840
With Faston Terminations