Vega Customer Applications Manual
Section 1 - Connection
Rev. A3: October 2003
Page 3 of 48
Section 1 - Connection
Connecting Vega to the input supply.
The AC input connection is situated adjacent to the cooling fan inlet as shown above. The faston tabs are tin plated
6.3 x 0.8mm at 9mm centres. Connection is made using insulated 6.35mm 'faston' connectors rated at 15amps each.
Wire Size (awg)
AMP termination
Colour
22-18
2-520407-2
RED
16-14
3-520408-2
BLUE
A moulded connector housing is also available which accepts 3 low insertion force 'faston' connectors (fastons are
AMP 42100-2). The housing incorporates two locking tabs and a tywrap may be used for additional strain relief of the
AC cable. Kits of 25pcs including the moulded housing and faston connectors and ty-wraps are available, Lambda
part number = KT-AC-88537.