83-507-013 Rev. A
60
Send AA Hex followed by the address of the supply in binary. If not installed, the supply will
return a ‘1’. If installed, the supply will return a ‘0’.
7.10.5 Addressed commands without response
7.10.5.1 Acknowledge
SRQ
Send (0xE0 + Address) (1 byte binary - send 2 times sequentially). The supply will stop re-
sending SRQ. If Enable SRQ retransmission is active, it will remain active.
7.10.5.2
Re-enable SRQ with out reading/clearing the SEVE Register
Send A5 Hex followed by the address of the supply in binary and new SRQ’s generated by
new events in the Fault Event will be enabled without reading and clearing the Status Event
Register. All events previously recorded in the Fault Event Register must have been serviced
by the user’s software prior to this command to take affect.
Name
Bit Positions
Response
Description
Global
Commands
Disable MD Mode
1010 0000
None
Set supplies out of MD Mode (de-
fault)
Enable MD Mode
1010 0001
None
Set supplies into MD Mode
Disable SRQ
retransmission
1010 0010
None
Disable retransmission of SRQs by
supplies (default)
Enable SRQ
retransmission
1010 0011
None
Enable retransmission of SRQs by
supplies
Enable FLT Bit
1010 0100
None
Enable the FLT bit in the SENA
Register
Disconnect serial
communications
1011 1111
OK
All supplies will halt transmission and
enter the non-addressed state.
Addressed Com-
mands
Read Registers
100x xxxx
Register data
Non destructive read of all register. x
xxxx is the address of the supply in
binary.
Re-enable SRQ
Byte 1
1010 0101
Byte 2
xxxx xxxx
None
Re-enable SRQ without reading or
clearing the SEVE Register. xxxx
xxxx is the address of the supply in
binary. Works only in MD Mode.
Print Power On
Time
Byte 1
1010 0110
Byte 2
xxxx xxxx
Power On time
in minutes
Read the time the supply is active
under AC Power. xxxx xxxx is the
address of the supply in binary. Re-
turns a 32 Bit integer as 8 Hex bytes.
A ‘$’ sign is appended to the data
followed by a 2 byte check-sum. A
total of 11 bytes are returned.
Retransmit last
message
110x xxxx
Last message Retransmit last response from a
command. x xxxx is the address of
the supply in binary.
Содержание Genesys GENH 750W