83-507-013 Rev. A
11
NOTES:
*1: Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage.
*2: Minimum current is guaranteed to maximum 0.4% of the rated output current.
*3: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be de-
scribed as 100-240Vac (50/60Hz).
*4: At 100/200V input voltage and maximum output power.
*5: From 85
i
132Vac or 170
i
265Vac, constant load.
*6: From No-load to Full-load, constant input voltage. Measured at the sensing point in Remote Sense.
*7: For load voltage change, equal to the unit voltage rating, constant input voltage.
*8: For 6V models the ripple is measured at 2
i
6V output voltage and full output current. For other mod-
els, the ripple is measured at 10
i
100% output voltage and full output current.
*9: With rated, resistive load.
*10. For 6
i
300V models: Measured with JEITA RC-9131A (1:1) probe
For 600V model: Measured with (10:1) probe.
2.12 SUPPLEMENTAL CHARACTERISTICS
The supplemental characteristics give typical but non-warranted performance characteristics. The sup-
plemental characteristics are useful in assessing applications for the power supply. Several kinds of sup-
plemental characteristics are listed below.
1. Evaluation Data: Typical performance of the power supply.
2. Reliability Data: Reliability Performance of the power supply.
3. IEC1000 Data: Performance of the power supply under IEC1000 test conditions.
4. EMI Data: Typical EMI (conducted and radiated) performance of the power supply.
The supplemental characteristics data is held in each Lambda sales and service facility. For further de-
tails please contact the lambda office nearest you.