
Lake Shore Model 480 Fluxmeter User’s Manual
6-30
Computer Interface Operation
DFLT 99
Set To Factory Defaults.
Input:
DFLT 99
Returned:
Nothing.
Remarks:
Used to reset the instrument to default values and to clear the user-entered coil parameters.
Does not clear instrument calibration.
DRAUTO
Initiate Auto Drift Correction.
Input:
DRAUTO
Returned:
Nothing.
Remarks:
Starts an Auto Drift Correction. Sets Fine DAC to 0 and adjusts Coarse DAC. This process
takes approximately 25 seconds to complete.
DRTHR
Set DriftTrak Threshold Level.
Input:
DRTHR nnnn
Returned:
Nothing.
Remarks:
Sets the threshold level of the DriftTrak function. This is the rate of change that will cause the
DriftTrak function to stop adjusting the DACs. Too small a value and DriftTrak will never
engage. Too large a value and DriftTrak will mistake a measurement signal for drift. The
number is a 4-digit integer and the units are µV·s/min. The default setting is 200 µV·s/min.
DRTHR?
Query DriftTrak Threshold Level.
Input:
DRTHR?
Returned:
nnnn
Remarks:
Queries the threshold level of the DriftTrak function. This is the rate of change that will cause
the DriftTrak function to stop adjusting the DACs. The number returned is a 4-digit integer
and is the units of µV·s/min.
DRTRAK
Configure DriftTrak Function Off/On.
Input:
DRTRAK <off/on>
Returned:
Nothing.
Remarks:
Configures the DriftTrak function.
0
= Off,
1
= On. The DriftTrak function continuously adjusts
the drift correction DACs when the instrument is not taking a measurement to minimize drift.
DRTRAK?
Query DriftTrak Function Off/On.
Input:
DRTRAK?
Returned:
0
or
1
. Format:
n[term]
.
Remarks:
Queries the DriftTrak function.
0
= Off,
1
= On.
END
Set End Or Identify (EOI) Parameter.
Input:
END <EOI enable>
Returned:
Nothing.
Remarks:
Sets the EOI parameter.
<EOI enable>
enables/disables EOI,
0
= enabled,
1
= disabled.
When enabled, the hardware EOI line becomes active with the last byte of a transfer. The
EOI identifies the last byte allowing for variable length data transmissions.
END?
Query End Or Identify (EOI) Parameter.
Input:
END?
Returned:
0
or
1
. Format:
n[term]
.
Remarks:
Returns EOI parameter.
0
= EOI enabled,
1
= EOI disabled.
Содержание 480
Страница 6: ...Lake Shore Model 480 Fluxmeter User s Manual C This Page Intentionally Left Blank ...
Страница 12: ...Lake Shore Model 480 Fluxmeter User s Manual vi Table of Contents This Page Intentionally Left Blank ...
Страница 66: ...Lake Shore Model 480 Fluxmeter User s Manual 5 24 Advanced Operation This Page Intentionally Left Blank ...
Страница 102: ...Lake Shore Model 480 Fluxmeter User s Manual 6 36 Computer Interface Operation This Page Intentionally Left Blank ...