Mobile Dust Cyclone Manual
36
Figure 11: Control Box with cover removed
3.
Remove the motor and power cord connectors on the Terminal Block.
4.
Loosen the four bolts (circled in red, below) holding the (black) Mounting Plate to the Control Box.
Remove the Mounting Plate with Circuit Board and Terminal Block from Control Box.
Figure 12: Control Box components
5.
Remove the Terminal Block from the Mounting Plate by removing the two screws.
6.
Attach the Terminal Block to the new Mounting Plate, using the same two screws.
Use pliers to carefully
remove these two pins.
The connectors may
get damaged if pulled
by force.
Mounting Plate
Circuit Board
Terminal Block