Mobile Dust Cyclone Manual
33
5.
With the canister filter removed use a compressed air gun to thoroughly clean
between the pleats, both inside and outside.
RE-ASSEMBLING THE CANISTER FILTER AFTER CLEANING
6.
With the aid of another person, carefully re-insert the canister filter repeating step
1,2,3 and 4 in reverse.
ROUTINE INSPECTION
It is a good idea to routinely inspect any quality woodworking tool to keep it in optimum
condition. This includes inspecting all hardware for tightness, ensuring the filter is clean, and
cleaning debris and grime from any surfaces and moving parts.
TROUBLESHOOTING
Symptom
Possible Cause
Possible Solution
Machine does
not start or a
breaker trips.
Power supply switched OFF
or is faulty.
Wall fuse/circuit breaker is
blown/tripped.
Faulty remote control.
Remote receiver is faulty.
Incorrectly wired motor
connection.
On-board circuit breaker is
tripped.
Wiring is open/has high
resistance.
Faulty power switch.
Motor is at fault.
Confirm power supply is
ON
and has the
correct voltage.
Ensure adequate circuit size; install inlet
restrictor, replace weak breaker.
Replace batteries; ensure un-obstructed
line-of-sight and signal range.
Inspect receiver circuit board; replace if
faulty.
Rewire or call certified service technician
or electrician.
Allow motor to cool, improve ventilation,
press reset button.
Check for broken wires or poor
connections, repair as necessary.
Replace switch.
Test/repair/replace.
Содержание PFLUX2
Страница 12: ...Mobile Dust Cyclone Manual 11 CONTROL PANEL Figure 1A Control Panel...
Страница 40: ...Mobile Dust Cyclone Manual 39 EXPLODED VIEWS PARTS 2021 10 14 SECTION A Close up view...
Страница 41: ...Mobile Dust Cyclone Manual 40 SECTION B Close up view...
Страница 42: ...Mobile Dust Cyclone Manual 41 SECTION C Close up view...
Страница 43: ...Mobile Dust Cyclone Manual 42 SECTION D Close up view...
Страница 44: ...Mobile Dust Cyclone Manual 43...
Страница 50: ...Mobile Dust Cyclone Manual 49 2021 Laguna Tools 120221...