1-57
GENERAL MAINTENANCE
1.14.4
PROPORTIONAL VALVE
Automizer
TM
units use an extra valve stack
to control the arm, the chute and the crusher
panel (if equipped) (Figure #1.80). This
valve is on/off or proportional type, meaning
that the amount of flow coming out of it will
be according to the position of the spool.
This feature (proportional control) allows
infinite control of the speed and the
movement of the arm. The arm is powered
by a dual vane pump (see
section 1.14.9
“Dual Vane Pump”).
Each section of the valve is actuated by an
electrical coil, located under the valve. The
proportional valve sections are described as
follow from top to bottom on figure #1.81.
VALVE SECTION DESCRIPTION:
• Input/Output cover:
(Provided with main relief valve)
• Crusher panel section (optional; not
shown):
(Not proportional, with load sense relief)
• Grabber section (Open/Close):
(Not proportional, with load sense relief)
• Grabber section (Up/Down):
(Proportional, no load sense relief)
• Telescopic arm section (Extend/
Retract):
(Proportional, no load sense relief)
PROPORTIONAL VALVE
FIGURE #1.80
INPUT/OUTPUT
COVER
TELESCOPIC ARM
(Extend / Retract)
GRABBER
(Up / Down)
GRABBER
(Open /Close)
Содержание Automizer Versa Hand
Страница 2: ...AUTOMIZER VERSA HANDTM 1 2...
Страница 4: ...AUTOMIZER VERSA HANDTM 1 4...
Страница 8: ...AUTOMIZER VERSA HANDTM 1 8...
Страница 43: ...1 43 GENERAL MAINTENANCE FIGURE 1 59 STITCH WELDS FLOOR GUIDES 1 12 7 FLOOR GUIDE REPLACEMENT PROCEDURE Cont d...
Страница 58: ...AUTOMIZER VERSA HANDTM 1 58 FIGURE 1 81 INPUT OUTPUT COVER ELECTRICAL COILS...
Страница 69: ...1 69 GENERAL MAINTENANCE FIGURE 1 89A Strainer Seal...
Страница 77: ...1 77 GENERAL MAINTENANCE A B C BEHIN D D F MAIN RELIEF B E...
Страница 105: ...1 105 GENERAL MAINTENANCE NOTES...